Figure 4
Toe kick screw
All manuals and user guides at all-guides.com
ELECTRICAL CONNECTION
Toe kick (Front Grille)
5
•
Do not splash or spray water from a hose on the wine
cellar. Doing so may cause an electrical shock, which may
result in severe injury or death.
•
This unit should not, under any circumstances, be installed
to an un-grounded power supply.
Electrical Connection
A grounded 115 volt, 15 amp dedicated circuit is required.
This product is factory equipped with a power supply cord that
has a three-pronged, grounded plug. It must be plugged into a
mating grounding type receptacle in accordance with the Na-
tional Electrical Code and applicable local codes and ordinances
(see Figure 5). If the circuit does not have a grounding type re-
ceptacle, it is the responsibility and obligation of the customer to
provide the proper power supply. The third ground prong should
not, under any circumstances, be cut or removed.
The unit must be installed according to your local building codes
and ordinances.
NOTE
Ground fault circuit interrupters (GFCI) are prone to nuisance
tripping which will cause the unit to shut down. GFCI's are gener-
ally not used on circuits which power equipment that must run
unattended for long periods of time, unless required to meet
local building codes and ordinances.
Do not use an extension cord with
this appliance.
Figure 5