Materials containing asbestos may only be worked by
specialists.
– Provide for good ventilation of the working place.
– It is recommended to wear a P2 filterclass respirator.
Observe the relevant regulations in your country for the
materials to be worked.
Operation
Starting Operation
Observe correct mains voltage! The voltage of
the power source must agree with the voltage
specified on the nameplate of the machine. Power
tools marked with 230 V can also be operated with
220 V.
Reversing the Rotational Direction (see figure C)
The rotational direction switch 7 is used to reverse the
rotational direction of the machine. However, this is not
possible with the On/Off switch 6 actuated.
Right Rotation: For drilling and driving in screws, push
the rotational direction switch 7 left to the stop.
Left Rotation: For loosening and unscrewing screws and
nuts, press th e rotational direction switch 7 through to the
right stop.
Switching On and Off
To start the machine, press the On/Off switch 6 and keep
it pressed.
To lock the pressed On/Off switch 6, press the lock-on
button 5.
To switch off the machine, release the On/Off switch 6 or
when it is locked with the lock-on button 5, briefly press
the On/Off switch 6 and then release it.
Adjusting the Speed
The speed of the switched on power tool can be variably
adjusted, depending on how far the On/Off switch 6 is
pressed.
Light pressure on the On/Off switch 6 results in a low
rotational speed. Further pressure on the switch results in
an increase in speed.
Working Advice
Apply the power tool to the screw/nut only when it is
switched off. Rotating tool inserts can slip off.
For drilling in metal, use only perfectly sharpened HSS
drill bits (HSS=high-speed steel). The appropriate quality
is guaranteed by the Stayer accessories program.
ENGLISH
12

Maintenance and Service

Maintenance and Cleaning
- Before any work on the machine itself, pull the
mains plug.
- For safe and proper working, always keep the ma-
chine and ventilation slots clean.
If the replacement of the supply cord is necessary, this
has to be done by Stayer or an authorized Stayer service
agent in order to avoid a safety hazard.
If the machine should fail despite the care taken in
manufacturing and testing procedures, repair should be
carried out by an after-sales service centre for Stayer
power tools.
Marked regulatory
Power input
Idling speed
L
Sound power level
WA
L
Sound pressure level
PA
Vibration
Weight
These data are valid for nominal voltages [ U] of 230/240
V ~ 50/60 Hz - 110/120 V ~ 60 Hz values can vary lower
voltage , and the models for specific countries. Please
observe the article number on the nameplate of the device,
as the trade names of the individual machines may vary.
Disposal
The machine, accessories and packaging should be
sorted for environmental-friendly recycling.
Only for EC countries:
Do not dispose of power tools into household waste!
According the European Guideline 2002/96/
EC for Waste Electrical and Electronic
Equipment and its implementation into national
right, power tools that are no longer usable
must be collected separately and disposed of
in an environmentally correct manner.
Subject to change without notice.