Frequency (automatic range)
Range
5 Hz
50 Hz
500 Hz
5 KHz
50 KHz
500KHz
10 MHz
Sensitivity: <0.5V RMS ≤ 1MHz
Sensitivity: >3V RMS < 1 MHz
Overload protection: 250V DC or AC rms
Duty Cycle
Range
0.1%-99.9%
Pulse width:>100µs, <100ms
Frequency width: 5Hz-150Hz
Sensitivity: <0.5V RMS
Overload protection: 250V DC or AC rms
All manuals and user guides at all-guides.com
Resolution
0.001Hz
0.01Hz
0.1Hz
1 Hz
10 Hz
100Hz
1KHz
Resolution
0.1Hz
11
Accuracy
±1.5% of rdg ±5dgt
±1.2% of rdg ±3dgt
±1.5% of rdg ±4dgt
Accuracy
±1.2% of rdg ±2dgt