Télécharger Imprimer la page

Danfoss CF-RS Manuel D'instructions page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
All manuals and user guides at all-guides.com
Instruction CF-RS Standard Room Thermostat
2. Installation
Note:
• To activate batteries in the Room Thermostat please
remove enclosed strips from the batteries
• The assignment of the Room Thermostats to the Master
Controller should be within 1½m distance
Activate Install mode on Master Controller - fig. 1
• Use the menu selection button
Install mode. Install LED
• Activate Install mode by pressing OK
LED
goes ON
Activate Install mode on Room Thermostat
• Press the push button
during communication
Select output onMaster Controller
• All available output LEDs on Master Controller
light up, and the first of them flashes
• Press output selection button
output (flashes) and accept with OK
• All output LEDs
stays ON shortly
Room Thermostat installation status
• Satisfactory - LED
• Not satisfactory - LED
Note: A Room Thermostat can be assigned to several
outputs if needed by repeating the installation process.
VI.UH.L4.1C
flashes
. LED
go OFF. Selected output
goes OFF
flashes 5 times
Produced by Danfoss Floor Heating Hydronics 03.2007
to select the
. Install
and
flicker
, select desired
GB
5

Publicité

loading

Ce manuel est également adapté pour:

088u0210