Gas Requirements
Provide Adequate Gas Supply
This oven's installation must conform to local codes or, in their absence, with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54.
This range's cooktop is designed to operate at a manifold pressure of 5 in. (13 cm) of water column for natural
gas/natural gas at high altitude (NG-H) or 10 in. (25.4 cm) of water column for LP (propane)/LP at high altitude
(LP-H).
Verify that the oven is right for the provided gas service.
When verifying regulator function, inlet pressure must be at least 1 in. (2.5 cm) greater than the operating
(manifold) pressure as given.
Gas Type
Natural Gas
LP (propane) Gas
* The gas supply pressure for testing the regulator setting shall be at least 1" water column (249 Pa) above the
specified manifold pressure;
**Maximum gas supply pressure for all models: 1/2 psi.
NOTE
The pressure regulator at the inlet of the cooktop manifold must stay in the supply line whether or not
natural or LP gas is used.
Use only the range's regulator, which must be installed in the gas line that runs from the cooktop gas inlet to
the gas shut-off valve.
An external manual shut-off valve must be installed between the gas inlet and range for turning on/off gas
to the appliance.
Ensure the connectors are installed by a qualified installer.
To avoid leaks and personal injury, never install used connectors on a new product. Use only new, flexible
connectors.
Special Gas Requirements (gas models sold in Massachusetts)
WARNING
Gas leaks may occur in your system, creating a hazardous condition. Such leaks may not be detected
by smell alone; thus, gas suppliers recommend installing a UL-approved gas detector per manufacturer
specifications.
The range must be installed by a plumber or gas fitter certified by the State of Massachusetts.
A T-handle manual gas valve MUST be installed in the gas-supply line to your range.
If using a flexible gas connector, multiple lines must not be connected in series.
INSTALL_DOP48C96DLS_DA_DG68-01511A-00_EN+MES+CFR.indb 17
INSTALL_DOP48C96DLS_DA_DG68-01511A-00_EN+MES+CFR.indb 17
GAS SUPPLY PRESSURE REQUIREMENTS*
Minimum Manifold Pressure
5" Water Column
10" Water Column
Minimum Gas Supply Pressure**
6" Water Column
11" Water Column
English 17
2023-02-23 오전 9:45:25