Viewing Live Images on a Monitor
All the power supplied to the system should be turned off when you connect devices.
Thicker than RG-6U (5C-2V): 500 m / 547 yds. max.
(Non-PoE power supply)
Power Supply Connection
To prevent a fire hazard use any UL listed
wire rated VW-1.
AC 24V
Check that +/– polarity is correct.
DC 12V
1 Thicker than 18 AWG
Alarm Signal Output
If a lamp is connected to this cable, it will
light up when an alarm signal is received
or when the built-in motion sensor detects
movement.
External
peripheral
equipment
• To use the ALARM OUT setting, you must
make the appropriate ALARM OUT
settings for CAMERA SETTINGS in the
network settings.
All manuals and user guides at all-guides.com
Monitor Connection
Using different cables from those specified here may
attenuate the video and/or sync signals and interfere with
correct transmission.
1
~
~
GND
1
+
–
(ALARM OUT)
(COM)
(Basic Connections)
POWER VIDEO OUT
GND
CLASS 2 WIRING
Thicker than 24 AWG, 600 m / 656 yds. max.
Alarm Signal Input
Alarm
input
signal
• To use the ALARM IN setting, you must
make the appropriate ALARM IN settings
for CAMERA SETTINGS in the network
settings.
6
ALARM OUT
ALARM IN
COM
LAN
LINK
(ALARM IN)