TECHNICAL DATA
Cordless percussion drill/driver
Drilling capacity in steel ...........................................................
Drilling capacity in wood ..........................................................
Wood screws (without pre-drilling) ..........................................
No-load speed 1st gear ...........................................................
No-load speed 2nd gear ..........................................................
Torque with battery *1 .............................................................
Battery voltage.........................................................................
Drill chuck range ......................................................................
Weight according EPTA-Procedure 01/2003 (3.0 Ah) .............
Noise/vibration information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K = 3 dB(A)) .......................................
Sound power level (K = 3 dB(A)) ............................................
Always wear ear protectors!
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Vibration emission value a
h
Drilling into metal ..................................................................
Uncertainty K= ......................................................................
Screwing ...............................................................................
Uncertainty K= ......................................................................
*1 Measured according to Milwaukee standard N 877318
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all
instructions, including those given in the accompanying
brochure. Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Wear ear protectors when impact drilling. Exposure to
noise can cause hearing loss.
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory
may contact hidden wiring. Cutting accessory contacting
a "live" wire may make exposed metal parts of the power
tool "live" and could give the operator an electric shock.
Hold power tool by insulated gripping surfaces, when
performing an operation where the fastener may
contact hidden wiring. Fasteners contacting a "live" wire
may make exposed metal parts of the power tool "live" and
could give the operator an electric shock.
Use auxiliary handle(s), if supplied with the tool. Loss of
control can cause personal injury.
Sawdust and splinters must not be removed while the
machine is running.
When working in walls ceiling, or floor, take care to avoid
electric cables and gas or waterpipes.
Remove the battery pack before starting any work on the
machine.
Do not dispose of used battery packs in the household
refuse or by burning them. Milwaukee Distributors offer to
retrieve old batteries to protect our environment.
20
ENGLISH
M18 CDD-22C
M18 CDD-32C
(1,5 Ah)
(3,0 Ah)
...........................13 mm ..........................13 mm
...........................45 mm ..........................50 mm
.............................9 mm ............................9 mm
......................0-550 min
-1
....................0-550 min
-1
....................0-1850 min
-1
..................0-1850 min
-1
...........................70 Nm ...........................80 Nm
...........................18 V ..............................18 V
.....................1,5-13 mm ....................1,5-13 mm
..........................2,0 kg ............................2,3 kg
...........................76 dB (A) ......................76 dB (A)
...........................87 dB (A) ......................87 dB (A)
........................1,32 m/s
2
.......................1,32 m/s
2
........................2,28 m/s
.......................2,28 m/s
2
2
........................1,32 m/s
.......................1,32 m/s
2
2
........................2,28 m/s
.......................2,28 m/s
2
2
Do not store the battery pack together with metal objects
(short circuit risk).
Use only System C18 chargers for charging System C18
battery packs. Do not use battery packs from other systems.
Battery acid may leak from damaged batteries under
extreme load or extreme temperatures. In case of contact
with battery acid wash it off immediately with soap and
water. In case of eye contact rinse thoroughly for at least 10
minutes and immediately seek medical attention.
SPECIFIED CONDITIONS OF USE
The battery drill/screwdriver may be used for drilling and
screwdriving for independent use away from mains supply.
Do not use this product in any other way as stated for
normal use.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is
in conformity with the following standards or standardized
documents. EN 60745, EN 55014-1, EN 55014-2, in
accordance with the regulations 2006/42/EC, 2004/108/EC
Winnenden, 2011-10-19
Rainer Kumpf
Manager Product Development
Authorized to compile the technical file
BATTERIES
New battery packs reach full loading capacity after 4 - 5
chargings and dischargings. Battery packs which have not
been used for some time should be recharged before use.
Temperatures in excess of 50°C (122°F) reduce the
performance of the battery pack. Avoid extended exposure
to heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept
clean.
For an optimum life-time, the battery packs have to be fully
charged, after used.
To obtain the longest possible battery life remove the battery
pack from the charger once it is fully charged.
For battery pack storage longer than 30 days:
Store the battery pack where the temperature is below 27°C
and away from moisture
Store the battery packs in a 30% - 50% charged condition
Every six months of storage, charge the pack as normal.
BATTERY PACK PROTECTION
In extremely high torque, binding, stalling and short circuit
situations that cause high current draw, the tool will vibrate
for about 2 seconds and then the tool will turn OFF.
To reset, release the trigger.
Under extreme circumstances, the internal temperatur of the
battery could become to high. If this happens, the battery
will shut down.
Place the battery on the charger to charge and reset it.
INTENANCE
Use only Milwaukee accessories and spare parts. Should
components need to be replaced which have not been
described, please contact one of our Milwaukee service
agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the Article No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: Milwaukee Electric Tool,
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before
starting the machine.
Remove the battery pack before starting any
work on the machine.
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2002/96/EC on waste
electrical and electronic equipment and its
implementation in accordance with national law,
electric tools that have reached the end of their
life must be collected separately and returned to