All manuals and user guides at all-guides.com
ENG
- Noise
Check if the circuit is spoilt. (Change the circuit)
Check if the connector is wet or rusty (Change the connector)
- Ring once then disconnect when receiving a call. Dialing function is still
available
Check if connector is in a moist environment.
Check if too many extensions are used together or the quality of extension is not
good enough (Change the bad extension)
- LCD become dim
Check if LCD contrast is properly set or if the batteries are weak. (Adjust LCD contrast,
if the LCD is still dim, replace the batteries.)
- No ring
Check if the RING is in the OFF state (reset it).
- Most of the functions failed
Check if the batteries are strong enough. (Change the batteries)
If batteries are ok (Remove the battery, unplug the lines and reinstall after 10
minutes)
NOTE: Due to continuous product development, all features and specifi cations are
subject to change without prior notice.
STATEMENT OF COMPLIANCE
Flamagas S.A. hereby declares that the DTC-400 product complies with the
requisites and basic safety requirements of Directive 1999/5/EC on Radio and
Telecommunications Terminal Equipment.
For a full copy of the statement of compliance please see:
www.electronicafl amagas.com
GARANTEE
This product is guaranteed against all manufacturing defects for 2 years from the
date of purchase.
If the care advice and instructions contained in this manual are not followed the
guarantee will be automatically void.
For this guarantee to be valid, it is necessary to present the original receipt or
invoice. Flamagas S.A. exclusive importer.
21