liquids may accumulate. Please keep a minimum dis-
tance of 5 m to swimming pools, ponds etc.
The floodlight must not be mounted on or near flamma-
ble surfaces.
The LED floodlight should not be mounted near flam-
mable and moving objects, such as furniture, decorative
material, curtains, candles, etc.
Mount the LED floodlight only on a stable surface
(wall/ceiling). The installation site must be stable and
must not be exposed to vibrations. Depending on the
substrate, use suitable screws and dowels.
The LED floodlight must be protected on the sub-
distribution board by a 10/16A fuse. An earth leakage
circuit breaker must be installed before this (FI protec-
tive switch).
The LED floodlight must be disconnected from the pow-
er supply during installation. It is not sufficient to just
turn off at the light switch!
Turn the power off by removing the corresponding cir-
cuit fuse or switch off at the circuit breaker. Secure it
against an unauthorised re-start, e.g. with a danger
sign. In addition, switch off the associated earth-leakage
circuit breaker.
Check that the mains connection is current free with a
suitable tester.
The earth protection cable must be connected when
installing the LED floodlight.
Operation
14