The humidity can be increased by increments of 5%RH
during normal mode. Hold this button for 1 second to
increase the humidity continuously.
(4)
The humidity can be decreased by increments of 5%RH
during normal mode. Hold this button for 1 second to
decrease the humidity continuously.
Note:
1) The default humidity is 50%RH, to increase and decrease
as follow:
20%-25%--30%-35%-40%45%-50%-55%-60%-65%-70%
-75%-80%-85%-90%
2) Environmental humidity and machine set humidity will
decide the status of the compressor and fan as follow:
compressor and fan start running.
Environmental humidity<
compressor and fan stop running.
(5)
During continuous mode, humidity setting is unavailable.
Continuous mode light turns on and the screen will display
the current humidity. Press this button to switch to normal
mode where the humidity setting will be available.
.2 Operation
1) When the water tank is full, the water tank light goes on
red and alarm goes on after 5 seconds. Buzzer beeps 15
times and the compressor and fan shut off. After the water
tank is emptied, the machine will automatically switch to
the previous mode while the compressor will be in 3
minutes of self-protect. Alarm will stop in 3 seconds after
the water tank was emptied and put back, fan starts, and
compressor will start in 3 minutes.
2) Compressor will not need 3 minutes for self-protect if it
was the first time to start the machine, press "POWER" and
power off; power on, press "POWER", compressor starts
immediately.
3) The system has auto memory. When all the mode setting
has been finished, if there is sudden power cut during
operation, or the power jack slips out, the system may
store the current status before the power is cut and enter
the operation mode before power cut automatically after
power is supplied.
.3 Defrost Function
1) The compressor and fan will shut off when the
environmental temperature goes below 41 °F or above
100.4°F.
2) Defrost requirement: Compressor running for 30
30.2°F, (last for 10 seconds), compressor stops, defrost
starts, fan continues, defrost light turns on, when the pipe
temperature goes to 41°F or the defrost last for 15
minutes, defrost stops.
Note: During defrost, light won't be off until the defrosting is
over.