8. MACHINE STORAGE
If you don't use the unit for an extended period of
time, please store it per the following steps:
(1) Clean the filter mesh.
(2) ATTENTION: The evaporator inside the machine has to
be dried out before the unit is packed to avoid component
damage and molds. Unplug the unit and place it in a dry
open area for days to dry it out. Another way to dry the unit
is to set the humidity point more than 2% higher than the
ambient humidity to force the fan to dry the evaporator for
a couple of hours.
(3) Store the power cord pocket at the back of unit.
(4) Store in a clean, dry environment.
9. TROUBLE SHOOTING
Trouble
Cause
Machine
Unit is not plugged in.
does not
Room temperature under
run
41 degrees or above
degrees F.
Machine
When the humidity set
runs but
point is 2% higher than
does not
ambient humidity.
dehumidify
Solution
Plug in the unit.
To protect the machine,
use it only when ambient
temperature is between 5
and 38 degrees.
Reset the humidity to a
lower set point, or power
off the machine if the
humidity has satisfied
you.
Reduce
Filter mesh jammed.
dehumidifier
capacity
Air-in and/or Air-out
louvers jammed.
No air inlet
Filter mesh or air-in
louver jammed.
Loud
Machine situated on an
Operation
incline or decline slope.
Filter mesh jammed.
Cautions: Switch off the unit and unplug it
immediately if anything abnormal happens. Then
contact a qualified personnel.
Do not dispose of electrical appliances as unsorted
municipal waste, use separate collection facilities.
Contact your local regulation for information regarding the
collection systems available.
Clean the filter mesh
according to manual.
Clear the blockage from
Air-in and/or Air-out
louvers.
Clean filter according to
instructions or clean the
louver blockage.
Move to flat ground.
Clean filter mesh
according to instructions.

Publicité