. ERROR
(1)
"E1": If the copper head sensor failure, it will show
"E1". The system works in cycles of dehumidification for 20
minutes and defrosting for 15 minutes. Copper head
sensor should be replaced with a new one.
(2)
"E2": If the humidity sensor got failure, it will show "E2".
The humidity adjusting button will not work. The system
works in cycles of dehumidification for 15 minutes and
defrosting for 15 minutes. Failure humidity sensor should be
replaced with a new one.
(3)
"FL": When the water tank is full, it will show "FL".
The machine will make a buzzing sound and stop working.
Remove the water form the tank and installed properly.
1
. MAINTENANCE
.1 Clean the machine with a soft wet cloth.
.2 Pull the louver on the front panel out to gain
access to the filter.
.3 Remove the filter mesh out of the unit.
.4 Use a clean rag to adsorb the surface dust on
the filter mesh.
If the filter is extremely dirty, use tap water to
flush the filter. Fully dry the filter before putting it back into the air
inlet fence. A clean filter will increase the machine's efficiency.