Télécharger Imprimer la page

Costway ES10111US-GR Mode D'emploi page 4

Publicité

Les langues disponibles

Les langues disponibles

Do not clean the appliance with any chemicals.
Ensure the unit is far away from fire, inflammable, or explosive
objects.
The unit shall be installed in accordance with national wiring
regulations.
Do not use means to accelerate the defrosting process or to
clean, other than those recommended by the manufacturer.
The appliance shall be stored in a room without continuously
operation sources (for example: open flames, an operating gas
appliance or an operating electric heater).
The appliance shall be stored so as to prevent mechanical
damage from occurring.
Do not piece or burn, even after use.
Be aware that refrigerants may not contain an odor.
Pipe-work shall be protected from physical damage and shall not
be installed in an unventilated space, if that space is smaller than 4
m²/43sq.ft.
Compliance with national gas regulations shall be observed.
Keep any required ventilation openings clear of obstruction.
The appliance shall be stored in a well-ventilated area where the
room size corresponds to the room area as specified for operation.
Any person who is involved with working on or breaking
into a refrigerant circuit should hold a current valid
certificate from an industry-accredited assessment
authority, which authorizes their competence to handle
WARNING
refrigerants safely in accordance with an industry,
recognized assessment specification.
Servicing shall only be performed as recommended by
the equipment manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel shall
WARNING
be carried out under the supervision of the person
competent in the use of flammable refrigerants.
06
2.2SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the followings
when servicing an appliance with R32.
2.2.1 Checks to the area
Prior to beginning work on systems containing flammable
refrigerants, safety checks are necessary to ensure that the risk of
ignition is minimized. For repair to the refrigerating system, the
following precautions shall be complied with prior to conducting
work on the system.
2.2.2 Work procedure
Work shall be undertaken under a controlled procedure so as to
minimize the risk of a flammable gas or vapor being present while
the work is being performed.
2.2.3 General work area
All maintenance staff and others working in the local area shall be
instructed on the nature of work being carried out. Work in
confined spaces shall be avoided. The area around the work space
shall be sectioned off. Ensure that the conditions within the area
have been made safe by control of flammable material.
2.2.4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector
prior to and during work, to ensure the technician is aware of
potentially flammable atmospheres. Ensure that the leak detection
equipment being used is suitable for use with flammable
refrigerants, i.e. no sparking, adequately sealed or intrinsically
safe.
2.2.5 Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment
or any associated parts, appropriate fire extinguishing equipment
shall be available to hand. Have a dry powder or CO2 fire
extinguisher adjacent to the charging area.