TECHNICAL SPECIFICATIONS
INPUT
Current .................................................................. 0/4-20mA
Selection at terminals .................................... SINK / SOURCE
Isolated power for passive loops .......................24V @ 25mA
Input impedance (with protection) ................................. 30Ω
Protected against overcurrents ............................ max 500mA
ACCURACY
Overall maximum error ................................................ 0.03%
Linearity error ........................................................... <0.02%
Thermal drift ............................................................ 0.5µA/ºC
MTBF....................................................................... >500000h
OUTPUTS
Current ..................................................4-20mA / 0-20mA DC
Maximum load capacity ............................................... ≤500Ω
Protection ...................................................... Reverse polarity
Current limitation ...........................................................25 mA
ISOLATION
Isolation voltage input / output 1 ............................ 3000VAC
Isolation voltage input / output 2 ............................ 3000VAC
Isolation voltage output 1 / output 2 ....................... 1500VAC
Isolation voltage supply / outputs (1-2) .................. 1500VAC
CONNECTIONS
7 6 5 4 3 2 1
I N P U T
SINK/SOURCE
P O W E R S U P P L Y
DIMENSIONS
WIRING
6...1
O U T P U T
SOURCE
DISEÑOS Y TECNOLOGÍA, S.A.
Xarol, 6B
P.I. Les Guixeres
08915 Badalona (Barcelona) - Spain
POWER SUPPLY
Supply voltaje ...................................................................... 24VDC
Voltage range ..............................................................15 to 30VDC
Maximum consumption ............................................................2.5W
ENVIRONMENTAL CONDITIONS
Operating temperature ........................................ –25ºC to +70ºC
Storage temperatura ............................................-50ºC to +105ºC
Heating time ................................................................. 5 minutes
Temperature coefficient ............................................... 35ppm / ºC
FORMAT
Protection .............................................................................. IP20
Material ................................................................Polyamide PA6.6
Weight (1 Channel / 2 Channels) ............................................85g
UL Combustibility ....................................................................... V0
Mounting ................................................................... rail EN50022
WIRING
Screw terminals M3 ................................................ torque 0.5Nm
Connection cable ............................................≤2.5mm² (12AWG)
INPUT (SOURCE)
PIN 1
N.C.
PIN 2
+ IN1
PIN 3
- IN1
INPUT (SINK )
PIN 1
+ EXC
PIN 2
- IN
PIN 3
N.C.
OUTPUT 1
PIN 4
+ OUT1
PIN 5
N.C.
PIN 6
- OUT1
OUTPUT 2
PIN 7
+OUT2
PIN 8
N.C.
PIN 9
-OUT2
POWER SUPPLY
PIN 10
+24V
PIN 11
N.C.
PIN 12
0V
CE Conformity.
Directives
Standarts
ATTENTION: If this instrument is not installed and used in accordance with
these instructions, the protection it provides against hazards may be
impaired.
To meet the requirements of EN 61010-1, where the unit is permanently connected
to the main power supply, it is mandatory to install a circuit-breaking device easily
accessible to the operator and clearly marked as a disconnect device.
According to 2012/19/EU Directive, You cannot dispose of it at the end
of its lifetime as unsorted municipal waste. You can give it back,
without any cost, to the place where it was adquired to proceed to its
controlled treatment and recycling.
Tel. +34 933 394 758
Fax +34 934 903 145
Email: comercial@ditel.es ; web: www.ditel.es
7
RAIL MOUNTING
EMC 2014/30/EU
LVD 2014/35/EU
EN 61000-6-2
EN 61010-1
EN 61000-6-3
20221007