UPLOAD DATA TO PC SOFTWARE
NOTE Download and install the software before
uploading the data.
NOTE The USB is used for uploading data only. It does
not support battery charging
Visit our website weather.oregonscientific.com for the
PC software.
1. Plug one end of the USB cable into the base station's
USB port and the other end into the PC's USB port.
The main unit displays
2. Uploading will start immediately.
NOTE
This product should be supplied by an identical
USB port complying with the requirements of Limited
Power Source.
RESET
Press RESET to reset to the default settings.
SPECIFICATIONS
BASE STATION
L x W x H
180 x 110 x 47mm
(7.1 x 4.3 x 1.9 in)
Weight
286 g (10 ounces) without
batteries
Battery
6V adaptor; 3 x UM-3 (AA) 1.5V
INDOOR BAROMETER
Barometer unit
mb, inHg and mmHg
Measuring range
700 – 1050mb/hPa
Accuracy
+/- 7 mb/hPa
Altitude setting
Sea level
User setting for compensation
Weather display
Sunny, Partly Cloudy, Cloudy,
Rainy and Snowy
Memory
Historical data and bar chart for
last 24hrs
INDOOR TEMPERATURE
Temp. unit
°C / °F
Operating range
0°C to 50°C (-32°F to 122°F)
Accuracy
0°C - 40°C: +/- 1°C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
Memory
Current, Min and Max temp.
All manuals and user guides at all-guides.com
3
.
10
INDOOR RELATIVE HUMIDITY
Operating range
25% to 90%
Accuracy
25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Memory
Current, Min and Max
RADIO-CONTROLLED / ATOMIC CLOCK
Synchronization
Auto or disabled
Clock display
HH:MM:SS
Hour format
12hr AM/PM or 24hr
Calendar
DD/MM or MM/DD
Weekday in 6
(E, G, F, I, S, R)
languages
REMOTE WIND SENSOR UNIT
L x W x H
178 x 76 x 214 mm
(7 x 3 x 8.4 inches)
Weight
100 g (3.53 ounces) without
battery
Wind speed unit
m/s, knots, kph, mph
Speed accuracy
2 m/s ~ 10 m/s (+/- 3 m/s)
10 m/s ~ 56 m/s (+/- 10%)
Direction accuracy
16 positions
Transmission of
Approx. every 56 seconds
wind speed signal
Memory
Max wind speed
Power
2 x UM-3 (AA) 1.5V batteries
OUTDOOR TEMPERATURE / HUMIDITY UNIT
L x W x H
92 x 60 x 20 mm
(3.6 x 2.4 x 0.79 in)
Weight
62 g (2.22oz) without batteries
Humidity range
5% to 95%
Temp. unit
°C / °F
Temperature
-30°C to 60°C (-22°F to 140°F)
outdoor range
RF frequency
433 MHz
Range
Up to 100 meters (328 feet)
with no obstructions
Transmission
Approx. every 102 seconds
Channel no.
3
Power
2 x UM-4 (AAA) 1.5 V batteries
REMOTE RAIN GAUGE
L x W x H
114 x 114 x 145 mm
(4.5 x 4.5 x 5.7 inches)
Weight
241 g (8.5 oz) without batteries
Rainfall unit
Mm and in
Range
0 mm – 9999 mm
Accuracy
< 15 mm: +/- 1 mm
15 – 9999 mm: +/- 10%
Memory
Past 24 hrs, hourly from last
memory reset
Power
2 x UM-3 (AA) 1.5 V batteries