MODEL NO.
VOLTS/PH/HZ
NVC2000
460/3/60
420/380/3/50 4000
NVC2400
460/3/60
420/380/3/50 4150
NOTE: Electrical ratings based on 60HZ dryers
MODEL NO.
VOLTS/PH/HZ
NVC2000
460/3/60
420/380/3/50 3800
NVC2400
460/3/60
420/380/3/50 3900
NOTE: Electrical ratings based on 60HZ dryers
A
Specification information above accurate at time of publication. Refer to equipment serial label
for actual refrigerant charges and specifications for units.
All manuals and user guides at all-guides.com
15.0 ENGINEERING SPECIFICATIONS
WEIGHT
REFRIGERANT MAX. FUSE
LBS.
KG.
TYPE
LB-OZ
1812.0 R-404A
19-0
1880.0 R-404A
19-0
WEIGHT
REFRIGERANT MAX. FUSE
LBS.
KG.
TYPE
LB-OZ
1721
R-404A
11-0
1767
R-404A
11-0
NOTICE
Nirvana Cycling Refrigerated Dryer Models 2000-2400
http://air.ingersollrand.com
AIR COOLED CONDENSERS
COMPRESSOR RATINGS
MIN. CIRCUIT
SIZE
AMPACITY
HP
60
38.2
13.5
60
38.2
13.5
WATER COOLED CONDENSERS
COMPRESSOR RATINGS
MIN. CIRCUIT
SIZE
AMPACITY
HP
45
27.4
10.5
45
27.4
10.5
FAN RATINGS
RLA
LRA
QTY
HP
RLA
25.7
140.0
2
0.5
1.40
25.7
140.0
2
0.5
1.40
FAN RATINGS
RLA
LRA
QTY
HP
RLA
19.3
105.0
-
-
-
19.3
105.0
-
-
-
LRA
10.0
10.0
LRA
-
-
21