Pump EcoVISE, EcoFloVISE
Display and buttons
Start
When power is on display will flash [– – – – –].
Starting the pump is done with "Standby" button (H).
The pump will start with the highest preset speed (HIGH) for three minutes, in the so-called Primary mode to ensure that the
pipes system is evacuated of any air. After this, the pump returns to the preset speed.
The Primary mode is shown on display with a rotating symbol together with the speed. The Primary mode can be canceled by
pressing "Standby" button again.
Select speed:
There are three preset speeds of 1500, 2500 and 2900 rpm. Select speed using ECO, MED and HIGH buttons.
The three preset speeds can also be selected by connecting an external power switch to the pump signal cable (see connection
diagram).
Adjust speed:
During operation, the speed can be adjusted up or down by means of plus and minus buttons.
View engine status and settings:
Press the menu button to display engine status and current pump settings. Scroll through different values with plus and minus
buttons.
Return to current speed display is done automatically if no button is used within 30 seconds or by pressing the menu button.
Change settings
Press the configuration button if you want to change the pump settings.
Select the parameter to be changed with plus and minus buttons.
Press the configuration button again to change the value of the parameter. Change the value with plus and minus buttons.
Weekdays are shown on the display as numbers, for example, Monday to Friday appear as "d 1-5" (day one to five).
Further in this manual, all menus and parameters are described.
Dot indicator
Dot indicator will clarify what appears on the display:
EXT
– External power switch active
TMR
– Timer program active
MENU – Display of motor status / settings
CNFG – Configuration menu active
RPM
– Display of actual speed
Configuration
9
ENGLISH
Indicating dot
Menu
Standby