Pump EcoVISE, EcoFloVISE
Change preset weekly timer
If required, you can change the preset weekly timer programs, select which of the five weekly timer programs (TP1-TP5)
you want to change. Then select which hours (T1ON-T9OFF) to change.
The weekly timer program will automatically rename TPR.
Program a new weekly timer program
1. Select a weekly TPR program.
2. Start the program by setting values for hours 1 "T1On" and "T1Off".
3. Then continue with hours 2 etc.
Weekly timer program may have up to 9 hours; t1-t9.
To disable the Timer, both its start and stop time must be set to "00.00". If a factory reset is made, all hours will be reset.
Programming example:
Preset Weekly Timer 5, TP5
6 Timers are used, T1-T6
Mo-Fr: 10hr ECO, 10min HIGH morning, 13hr 50min MED
Sat-Sun: 12hr ECO, 1hr HIGH day, 11hr MED