T
roubleshooTIng
Problem
High Total Dissolved
Solids (TDS) in the
Poduct Water
(continued
Tastes and odors in
the Product
Water
Amber light on
optional water quality
monitor
Drain Water overflows
at the Air Gap Faucet
Faucet leaks or drips
Fitting leaks in general
All manuals and user guides at all-guides.com
g
C
'
uIde
on
T
Possible Cause
The Product Water and Drain Water
lines are reversed.
No drain flow, Drain Restrictor is
clogged.
No drain flow, the drain orifice in
the Air Gap Faucet is plugged.
The ASO Valve is not closing.
New Activated Carbon Post Filter not
rinsed completely.
The Feed Water TDS has increased.
The Activated Carbon Post Filter is
exhausted.
There is foreign matter in the Hold ing
Tank.
The Product Water and Drain Water
lines are reversed.
Dissolved gasses in the Feed Water.
Increase in Product Water TDS.
System not being used for extended
period of time.
Filters are plugged or membrane is
fouled or exhaused.
Air Gap is blocked.
Drain tubing is clogged.
Drain Clamp hole is misaligned.
Excessive drain flow rate.
Leaks from spout.
Leaks from base of the delivery
tube.
Leaks from beneath the handle.
Close the Feed Water Saddle Valve and relieve pressure before dis con nect ing
any tubing or re plac ing any fi tting. Before replacing a fi tting, re–cut the tubing
and re–insert into the fi tting to see if that solves the leak. If pipe threads are
leaking, remove and retape with Tefl on tape.
Solution
Correct plumbing.
Clear or replace Drain Restrictor.
Clear or replace Air Gap Faucet.
Repair or replace the ASO Valve
Components.
Flush with several full tanks of
Product Water.
An increase in Feed Water TDS will
give a corresponding increase in
Product Water TDS.
Replace Filter.
Clean, fl ush and sanitize the system.
Replace the fi lters.
Correct plumbing.
Pretreat Feed Water to remove
dissolved gasses.
See high TDS in the Product Water
section.
Empty storage tank. Wait 15 minutes
for the system to begin making water
and test water quality again.
Replace fi lters and/or membrane.
Clear Air Gap.
Rinse with vinegar for removal of
calcium buildup.
Clear tubing.
Align with hole in the drain pipe.
Replace Drain Restrictor.
Adjust Faucet by turning the tee bar
just below the handle to provide a
small amount of free play in handle
when shut off.
O–rings are bad, repair or replace
faucet.
O–ring is bad, replace O–ring.
O–rings are bad. Repair or replace
the faucet.