50 PSI Compressor
Assembly, Installation, and Operating Instructions
SAVE THESE INSTRUCTIONS
NOTE: Check ALL parts for shipping damage. If ship-
ping damage is noted, DO NOT use. Contact Carrier/
Dealer for further instruction.
SAFETY SUMMARY
The following recommendations are for the safe
use of the 50 PSI Compressor:
WARNINGS
"Caution: Federal law restricts this device to sale
by or on order of a physician, or any other practi-
tioner licensed by the law of the State in which he
practices to use or order the use of this device."
DO NOT USE WITHOUT FIRST READING AND UNDER-
STANDING THESE INSTRUCTIONS. IF YOU ARE UN-
ABLE TO UNDERSTAND THE WARNINGS AND IN-
STRUCTIONS, CONTACT INVACARE TECHNICAL
SERVICES (800- 832-4707) BEFORE PERFORMING
THIS INSTALLATION. IMPROPER USE MAY CAUSE
PERSONAL INJURY AND/OR EQUIPMENT DAMAGE.
SPECIFIC WARNINGS
TO REDUCE THE RISK OF ELECTRICAL SHOCK
OR INJURY TO PERSONS
DO NOT disassemble. Disassembly or attempted
repairs if accomplished incorrectly can create
electrical shock hazard. Only qualified techni-
cians should perform servicing of this compres-
sor unit.
If this unit is supplied with a three-pronged plug,
connect unit to a properly grounded outlet only.
Improper use of the grounding plug can result in
a risk of electric shock.
TO REDUCE THE RISK OF ELECTROCUTION,
EXPLOSION OR FIRE
This product should NEVER be left unattended
when plugged in.
ALWAYS unplug this product IMMEDIATELY after
using and store in a dry place.
DO NOT use this product where it can fall or be
pulled into water or other liquid.
DO NOT reach for product if it has fallen into liq-
uid. UNPLUG IMMEDIATELY.
All manuals and user guides at all-guides.com
1
SPECIFIC WARNINGS CONTINUED
DO NOT pump anything other than atmo-
spheric air.
NEVER operate this product outdoors in the rain
or in a wet area.
DO NOT use this product near flames.
DO NOT use the compressor for continuous op-
eration more than 10 hours, this can result in over-
heating and damage to the compressor.
NEVER operate this product if it has a damaged
cord or plug. If it is not working properly, if it has
been dropped or damaged, or if it has fallen
into water, return the product to a service center
for examination and repair.
DO NOT use this product in or near explosive
atmospheres or where aerosol (spray) products
are being used.
DO NOT pump combustible liquids or vapors with
this product or use in or near an area where flam-
mable or explosive liquids or vapors may exist.
Close supervision is necessary when this product
is used near children. NEVER allow children to
operate the unit.
Keep the cord away from HEATED surfaces.
NEVER block any air openings (inlet) of the prod-
uct or place it on a soft surface where the open-
ing may be blocked. Keep all air openings free
of lint, dirt and other foreign objects.
NEVER use while sleepy or drowsy.
NEVER drop or insert fingers or any other object
into any openings.
DO NOT operate this product in an oxygen enriched
environment, i.e. oxygen tent or oxygen hood.
This unit may be thermally protected and can auto-
matically restart when the protector resets. Always
disconnect power source before servicing.
Use only in well ventilated areas.
All electrical products generate heat. To avoid
serious burns NEVER touch unit during or im-
mediately after operation.
CAUTION
Compressors are precision-made and carefully
assembled and wired. Therefore DO NOT disas-
semble or attempt to repair these products. Only
qualified personnel should perform repair service.

Publicité

loading

Sommaire des Matières pour Invacare 50PSI

  • Page 1 (spray) products are being used. ABLE TO UNDERSTAND THE WARNINGS AND IN- STRUCTIONS, CONTACT INVACARE TECHNICAL DO NOT pump combustible liquids or vapors with SERVICES (800- 832-4707) BEFORE PERFORMING this product or use in or near an area where flam- THIS INSTALLATION.
  • Page 2 All manuals and user guides at all-guides.com REGULATORY LISTING IN ELECTRICAL COMPLIANCE WITH: Compressor UL 544 - Listed Medical and Dental Equipment If the overload protector shuts off the motor frequently, CSA C22.2 No. 125 - Certified Medical and Dental you may have a low voltage situation.
  • Page 3 All manuals and user guides at all-guides.com 4. Turn the pressure control knob fully counterclock- CLEANING/REPLACING THE AIR wise. FILTERS (FIGURE 2) NOTE: As the knob is turned counterclockwise the pres- NOTE: Check the filters at least once each month. sure will decrease, as the knob is turned clockwise the If the compressor begins to lose pressure in nor- pressure will increase.
  • Page 4 Upon receiving notice of an alleged defect in a product, Invacare will issue a serialized return autho- rization. It shall then be the responsibility of the purchaser to return, at purchaser’s cost, to either Invacare’s plant or service center as specified by Invacare in advance. Defective component part(s) must be returned for warranty inspection using the serial number as identification within thirty (30) days of return authorization date.
  • Page 5 NO bombee líquidos combustibles o vapores PÓNGASE EN CONTACTO CON EL DEPARTAMENTO con este producto. No lo use cerca de areas DE SERVICIOS TÉCNICOS DE INVACARE, (TEL. NO. 1- donde líquidos inflamables o vapores explosivos 800-832-4707), ANTES DE HACER LA INSTALACION.
  • Page 6 All manuals and user guides at all-guides.com PRECUACION NOTA: Consulte con un electricista o un técnico de servicio capacitado si tiene dificultad en comprender Estos compresores son hechos con precisión y completamente las instrucciones o si tiene alguna duda cuidadosamente ensamblados y alambrados. Por en cuanto a si el producto está...
  • Page 7 All manuals and user guides at all-guides.com Filtro OPERACION (FIGURA 2) Indicador de Presión Botón Salida de Aire ADVERTENCIA Para evitar daño físico, es necesario operar este Interruptor producto apropiadamente. El uso inapropiado puede causar heridas personales y/o daño al tejido.
  • Page 8 Invacare garantiza por un año, desde la fecha de compra, que los materiales y la mano de obra utilizados en el compresor Modelo IRC607 están libres de defectos. Si dentro del período de la garantía el producto cubierto por la misma fuera encontrado con algún defecto, el cual tiene que ser...
  • Page 9 STRUCTIONS, CONTACTER LE SERVICE TECHNIQUE ou inflammables pourraient être présents. INVACARE (800-832-4707) AVANT DE TENTER L'INSTALLATION. UNE MAUVAISE UTILISATION PEUT Une supervision étroite est nécessaire lorsque cet CAUSER DES BLESSURES ET/OU DES DOMMAGES appareil est utilisé...
  • Page 10 All manuals and user guides at all-guides.com Prise bipolaire Adapteur Prise avec ATTENTION mise à la terre temporaire Les compresseurs sont des appareils de précision, assemblés et filetés avec soins. NE PAS démonter ou tenter de réparer cet appareil. Seul un per- sonnel qualifié...
  • Page 11 All manuals and user guides at all-guides.com Ens. du filtre d’entrée FONCTIONNEMENT (FIGURE 2) Jauge de pression AVERTISSEMENT Bouton de Port de sortie Le fonctionnement adéquat de cet appareil est contrôle de nécessaire pour éviter les blessures. Une mauvaise Interrupteur pression utilisation peut causer des blessures et/ou des ON/OFF...
  • Page 12 Cette garantie vous donne des droits légaux spécifiques. D'autres droits variant d'un État à l'autre peuvent se rajouter. INVACARE garantit le compresseur 50 PSI contre tout défaut de fabrication ou défaut dans le matériel pour une période d'un (1) an à partir de la date d'achat. Si, durant cette période, ce produit devait s'avérer défectueux, ce dernier sera réparé...

Ce manuel est également adapté pour: