2.3.3
Connect the male connectors to wiring harness
Check which way the male connector plugs in to the vehicles's
connector. Push both wires of the wiring harness to the male
connector and make sure that the red wire (+) inserts to the same
side as the positive side was marked in the previous chapter.
The connector pair with the red shrink tube +12V (see image below)
must be connected so that eFlexFuel® gets its operating voltage.
2.3.4
Install the wiring harness to the fuel injectors
Once the male connectors are connected to the eFlexFuel® wiring
harness, it is ready to be installed.
CAUTION:
Do not change the order of the vehicle's original injector
connectors!
eFlexFuel® injector wires can be in any order.
•
Connect the male connectors of the eFlexFuel® wiring
harness to the vehicle's injector wires you disconnected
earlier. (Figure E, 1)
•
Connect the female connectors of the eFlexFuel® wiring
harness to the injectors. (Figure E, 2)
If your engine is equipped with secondary fuel injectors (e.g. 4 cylinders
=> 8 injectors), the wire with red heat shrink needs to be connecter to
primary connectors (closer to the cylinder head).
https://eflexfuel.com/