Télécharger Imprimer la page

BIG ASS FANS HORNET Guide D'installation page 3

Publicité

Les langues disponibles

Les langues disponibles

A suitable means for lifting the weight of the fan and at least two installation personnel will be
required.
Technical specifications
Diameter
38 in. (965 mm)
78 lb (35.4 kg)
Tools needed
10 mm
Additional tools may be required.
Electrical requirements
☑ Make sure the supply power circuit is the appropriate size and voltage and that power wiring is routed to a
junction box at the fan location.
☑ Make sure the fan is the correct voltage. The voltage is marked on the fan specification label and cannot be
changed during installation.
☑ For installations using the speed controller, install the fan on a switched circuit so that the fan can be turned
on and off after the speed controller is mounted at ceiling level.
Mounting guidelines
☑ A structural engineer should approve the mounting structure prior to installation.
☑ Big Ass Fans recommends installing the optional Stability Kit if the fan is exposed to high winds or similar
conditions or if the fan is close to any other sources of airflow.
☑ The fan is suitable for indoor installation only.
☑ If hanging the fan from an I-beam, the I-beam must be part of the existing building structure.
BEFORE YOU START
Weight
Input Power and Required Breaker
100–120 VAC, 50/60 Hz, 1 Ф, 15 A
200–240 VAC, 50/60 Hz, 1 Ф, 10 A
9/16"
WWW.BIGASSFANS.COM
20 ft·lb (27.1 N·m)
© 2023 DELTA T LLC
ALL RIGHTS RESERVED.
Max Current
Max Power
6.4 A
432 W
3.7 A
431 W
1