COMMISSIONING AND OPERATION
Timer (set time to automatically switch off)
When the dehumidifier is in operation, press the TIMER key to adjust the time
from 1 h - 24 h. If you press the button once, the time is set to 1 hour.
Pressing the button several times increases the time by one hour. If you press
the button again after 24
hours, the time starts at 1 again. If the time you set has elapsed, the appliance
switches off automatically. If no button is pressed within 5 seconds after the setting
is completed, the set time to switch off is confirmed. When the auto power off
time has been set, the timer indicator light will usually illuminate.
Timer (Setting the Time to Auto Power On)
When the unit is in standby mode, the auto power on time can be set in the same
way as the auto power off time (see above). If no button is pressed within 5
seconds after the setting is completed, the set time to power on is confirmed.
When the auto power on time has been set, the timer indicator light will usually
light up.
AUTO Mode
If you select the automatic mode, when the indoor humidity is 5% higher than the
target humidity, the compressor and fan will continue to run at the set speed. If
the indoor humidity is 5% lower than the target humidity, the compressor will
shut down, but the fan continues to run at the set speed. The factory-set humidity
value is 50%.
Continuous Mode
If you select this mode, the compressor will start regardless of relative humidity. The
factory setting is for the fan to run at maximum speed in this mode. The speed of the
air circulation can be adjusted using the speed button.