Télécharger Imprimer la page

MSW Motor Technics MWS-ETEH3000 Mode D'emploi page 25

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49
temperature
and fan
correctly.
The heater
becomes red.
The device does
not heat up,
only the fan is
running.
Noise during
operation,
strange noise.
Input voltage is too low or
too high.
Air inlet restricted /
blocked.
Temperature not set high
enough.
Thermostat failure.
The self-resetting thermal
fuse worked
Thermal fuse worked - not
self-resetting (only for
devices with one).
The device is not on an
even and stable surface.
For power supply, use the
power supply as required for
this device (see the technical
data table).
Place the unit away from any
curtains, walls, etc., so
elements that can restrict or
cut off the air supply.
Set a higher temperature.
Turn the temperature
setting knob and listen to
whether there is a "click"
during the action of turning,
i.e. whether the thermostat
opens / closes - if not, it is
probably damaged. If it is
not damaged, the heater will
turn on automatically after
the device cools down.
Turn off the unit and check
the air inlet and outlet for
any restrictions or blockages.
Unplug the power plug for at
least 10 minutes to reset the
thermal fuse.
Disconnect the device from
the power source, insert the
narrow tip into the hole of
the reset button on the
control panel and press this
button. Then reconnect the
power.
Place the device on an even
and stable surface.