4-7. Remote 14 Receptacle Information
A
J
K
I
B
C L N
H
M
D
G
F
E
*The remaining sockets are not used.
OM-234 199 Page 18
Socket*
A
24 VOLTS AC
B
I
115 VOLTS AC
J
C
D
REMOTE
OUTPUT
E
CONTROL
M
F
A/V
AMPERAGE
H
VOLTAGE
G
GND
K
Socket Information
24 volts AC. Protected by supplementary protect-
or CB2.
Contact closure to A completes 24 volts AC
contactor control circuit.
115 volts AC. Protected by supplementary pro-
tector CB1.
Contact closure to I completes 115 volts AC
contactor control circuit.
Output to remote control; 0 to +10 volts DC, +10
volts DC in MIG mode.
Remote control circuit common.
0 to +10 volts DC input command signal from
remote control.
CC/CV select
Current feedback; +1 volt DC per 100 amperes.
Voltage feedback; +1 volt DC per 10 output recep-
tacle volts.
Circuit common for 24 and 115 volt AC circuits.
Chassis common.