NOTES ON OPERATION
23(5$7,1* 7(03(5$785( 5$1*(
INDOOR TEMP.
upper
limit
&22/,1*
lower
limit
upper
limit
+($7,1*
lower
limit
7KH EXLOWLQ SURWHFWLYH GHYLFH PD\ SUHYHQW
the unit from operating when used out of this
range.
&RQGHQVDWLRQ PD\ IRUP RQ WKH DLU RXWOHW LI WKH
unit operates continuously in the COOL when
humidity is over 80 percent.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to
store settings when a power failure occurs.
After power recovery, the unit will
automatically re-start in the same settings
which were active before the power failure,
except for timer settings.
If the timers were set before a power failure, they
will need to be re-set after power recovery.
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not
VWDUW IRU WZR WR ¿YH PLQXWHV DIWHU WKH XQLW LV
turned on to prevent cold air from blowing out of
the unit.
DEFROSTING FUNCTION
:KHQ LFH IRUPV RQ WKH KHDW H[FKDQJHU LQ
the outdoor unit during the HEAT operation,
an automatic defrost provides heat for about
5 to 10 minutes to remove the ice. During
defrosting, the inside and outside fans stop
operating.During the defrosting operation, the
operation indicator blinks slowly.
$IWHU GHIURVWLQJ LV FRPSOHWHG WKH XQLW
automatically resumes operation in the HEAT
mode.
HEATING EFFICIENCY
7KH XQLW HPSOR\V D KHDW SXPS WKDW GUDZV KHDW
from the outside air and releases it into the
room. The outside air temperature therefore
JUHDWO\ DIIHFWV WKH KHDWLQJ HI¿FLHQF\
,I WKH KHDWLQJ HI¿FLHQF\ LV UHGXFHG GXH WR ORZ
outside temperatures, use an additional heater.
,W WDNHV WLPH WR ZDUP XS DQG KHDW WKH HQWLUH
room because of the forced air circulation
system.
OM-B142 ZU A5 EN.indd 22
OUTDOOR TEMP.
Û)
Û) Û&
Û&
Û)
Û) Û&
Û&
Û)
Û) Û&
Û&
–
Û) Û&
EN-22
NOTE
7KH ORZHVW RSHUDWLQJ WHPSHUDWXUH IRU +($7
is -27°C (-17°F). If outdoor temperature can
drop below -27°C (-17°F) in your area, we
recommend you to have another heating
source. When outdoor temperature actually
drops below -27°C (-17°F), turn off the unit to
SUHYHQW DQ\ GDPDJHV DV ZHOO DV LQHI¿FLHQW
performance.
IMPORTANT
)RU FROGHU FOLPDWH LQVWDOO WKH RXWGRRU XQLW
in a location not affected by snowfall or ice
(slope of roofs of houses for example). The
unit must be installed at least 10 inches
above the average snow accumulation in
your area. In heating mode, make sure the
snow is always 10 inches below the base
of the outdoor unit. The accumulation of
snow under the unit can affect the proper
operation of the unit and damage it. During
defrosting the drain holes in the outdoor unit
pan should always be free and let the water
ÀRZ WKUX LI WKHUH LV VQRZ EORFNLQJ WKH ÀRZ
of water the ice will accumulate and damage
the unit.
Always clear the snow and avoid
snow or ice buildup to prevent
damages to the AC unit.
10 inch
(254 mm)
clearance
above snow
buildup at
all times.