WIRING DIAGRAMS
WIRING OPTION #1
• When switch is ON, fan will operate automatical-
ly, based on room humidity conditions.
• Turn fan ON immediately for the set timer period
(to control odors), by cycling switch.
ON / OFF SWITCH
(PURCHASE SEPARATELY)
ON / OFF
SWITCH
BLK
120
WHT
VAC
LINE
GRD
IN
SWITCH BOX
8
GREY
BLK
BLK
BRN
HUMIDITY
CONTROL
WHT
GRD
UNIT
WIRING OPTION #2
• When first switch (1) is ON, fan will operate auto-
matically based on room humidity conditions.
• Turn fan ON immediately (to control odors) by using
second switch (2).
2-FUNCTION CONTROL
(PURCHASE SEPARATELY)
(2)
FAN
WHT
(ON/OFF)
FAN
COM
WHT
(1)
HUMIDITY
WHT
CONTROL
(AUTO/OFF)
BLK
120
WHT
VAC
LINE
GRD
IN
RED
GREY
HUMIDITY
CONTROL
BLK
BRN
WHT
GRD
SWITCH BOX
BLK
WHT
FAN
WHT
WHT
UNIT