Starting the Heater: (Ignition)
1. Fill the tank with kerosene or other approved fuel until
needle on fuel gauge points to "F".
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong (grounded) power
source. You must use a three prong (grounded)
extension cord that is at least 6 feet long and is a
minimum of 14 AWG rating.
4. Press the power button to power on the heater (see
Figure 3).
5. Select desired temperature using temperature +/-
buttons.
6. The heater will ignite once the temperature setting is
higher than the ambient temperature in the space.
Stopping / Restarting Heater:
To stop the heater, move the power switch to the "Off"
-
position and unplug the power cord.
To restart the heater; wait 10 seconds and follow ignition
-
steps.
Adjusting the Pump Pressure:
Remove the right side cover (4 screws). Behind the
-
panel, the pump will have a Phillips screw. There is
a small "P" next to the pump adjustment screw. Turn
screw in quarter turn increments.
Clockwise increases the pressure.
-
Counterclockwise decreases pressure.
-
© 2021 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
OPERATION (CONT.)
7
SDR 220 Rating Label + Control Panel
Model - Modelo
BTU/Hr - BTU/h
Fuel Consumption Gal./Hr.
Consumo de Combustible Gal./h
Fuel Tank Capacity Gal.
Capacidad del Depósito Gal.
Pump Pressure PSI - Presión de le Bomba
V~Hz/Amps - V~Hz/Amperes
TIP: If the heater does not ignite, the thermostat
Fuse - Fusible
Phase - Fase
may be set too low. Increase the temperature to a
Type of Fuel
higher setting until the heater ignites.
Tipo de aceite combustible
Maximum Air Outlet Temp. °F
Max. Temp. Del Aire De Salida °C
Minimum Distance From Combustibles:
Outlet: 8 ft. (250 cm) Sides / Top / Rear: 4 ft. (125 cm)
Minimas Distancias de Separacion de Materiales
TIP: If the heater does not ignite; press power
Combustibles:
Salida de Aire: 8 ft. (250 cm)
button to power off the heater, check steps 1-3
Lateral / Superior / Posterior: 4 ft. (125 cm)
See Operating Instructions and Troubleshooting on
above and press power button to power
side panel.
ON the heater.
Las instrucciones de Funcionamiento y soluciónes
de problemas se encuentran en el panel lateral.
COMPLIES WITH UL 733 AND
ANSIA 10.10-1998
CAN/CSA-B140.0-03 AND CSA B140.8-1967
© 2018 Pinnacle Climate Technologies, Inc.
www.masterindustrialproducts.com
°F
Figure 3
SilentDrive Forced Air Heater User's Manual
MH-220T-SDR
220,000
1.67
13
93
120V~60Hz / 3.15
3.15A
1Ø
No. 1 / Kerosene
No. 1 / Queroseno
1025
552
Made In China
Hecho en China
°F
MASC-004