Problem
Heater Ignites, but main PCB shuts
off after a short period of time.
LED display shows "E1."
Heater will not operate or motor
runs for a short time.
LED display shows "E1."
Fan does not operate when heater
is plugged in and power switch is
in the "ON" position. LED display
shows "E1" or "E2."
Poor combustion and / or excess
soot production.
Heater does not turn on and the
lamp is not lit.
© 2021 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
TROUBLESHOOTING GUIDE
Possible Cause
1.
Dirty fuel filter.
2. Nozzle is dirty.
3. Photocell lens is dirty.
4. Photocell not installed properly.
5. Photocell is defective.
6. Improper electrical connection
between main PCB and photocell.
1.
No kerosene in the fuel tank.
2. Corroded spark plug or incorrect
plug gap.
3. Dirty fuel filter.
4. Dirty nozzle.
5. Moisture in fuel tank.
6. Improper electrical connection
between transformer and circuit
board.
7.
Ignitor wire not connected to spark
plug.
8. Defective ignitor.
1.
Thermostat is set too low.
2. Broken electrical connection
between main PCB and motor.
1.
Dirty fuel filter.
2. Poor quality of fuel.
3. PSI is too high or too low.
1.
Temperature limit sensor has
overheated.
2. No electrical power.
3. Fuse is blown.
4. Improper electrical connection
between temperature limit sensor
and circuit board.
1.
2. Clean / replace Nozzle.
3. Clean / replace photocell.
4. Adjust photocell position
5. Replace photocell
6. Check wiring connections.
1.
2. Clean / replace spark plug.
3. Clean / replace fuel filter.
4. Clean / replace nozzle.
5. Rinse fuel tank with clean, fresh
6. Inspect all electrical connections.
7.
8. Replace ignitor.
1.
2. Inspect all electrical connections.
1.
2. Flush fuel tank and refuel heater.
3. Use proper pressure.
1.
2. Check power cords for proper
3. Check / replace the fuse.
4. Inspect all electrical connections.
SilentDrive Forced Air Heater User's Manual
11
Solution
Clean / replace fuel filter.
Fill tank with fresh kerosene.
kerosene.
Re-attach ignitor wire to spark plug.
Rotate thermostat to a higher setting
Clean / replace fuel filter.
Push power switch to "OFF and
allow heater to cool for 10 minutes.
Restart heater.
connection and test the power
supply.