OPERATING INSTRUCTIONS
C
D
D
Detergent Intake
Put the detergent tube (H) into the detergent bottle
and adjust the nozzle to the correct setting by
pulling the lance head out (- position). To restore
the standard pressure setting pull the lance back
(+ position).
Adjusting the working pressure
• The regulator is used to adjust the working
pressure. Turn clockwise for higher pressure, turn
counterclockwise for lower pressure.
96647_IM_620 630 630HW 630TSS 630TSSHW_1900PSI_ENG-FR-SP_A5_3L.indd 9
96647_IM_620 630 630HW 630TSS 630TSSHW_1900PSI_ENG-FR-SP_A5_3L.indd 9
H
• The quantity of detergent delivered is adjusted
using the regulator. Turn clockwise for large
delivery quantity, turn counterclockwise for small
D
delivery quantity.
Operation Tips
• Note: Test the GFCI before each use:
D
• If you hear the motor run intermittently when
• The o-rings on the bayonet end of the nozzle
• Keep the nozzle cleaning wire for use in
1. Plug GFCI into power outlet. Indicator should
turn green to show that cord has power.
2. Press test button, green indicator should
turn off to verify that GFCI cut off power to
the cord.
3. Press reset button – green indicator should
turn on to show that cord has power again.
4. When GFCI is working properly, green
indicator will turn on when power is applied.
If green indicator turns off, it has detected
electric leakage and the GFCI cut off power
to the appliance.
the trigger is not being squeezed, that is
normal. The pump is priming itself so it is ready
to operate when the trigger is squeezed. Turn
off the power washer if not being used after five
minutes.
should be cleaned regularly and lubricated with
non-water soluble grease such as petroleum jelly.
unclogging the nozzle. If you lose the cleaning
wire, a straightened paper clip also works.