OPERATION
Presence detection:
• Recognises user presence after 10 seconds within the detection zone: prevents accidental rinsing.
• Automatic rinsing when the user leaves and automatic timed shut-off after 2 seconds (can be adjusted
to 3 seconds depending on the programme).
High-frequency mode (less than 20 seconds between 2 users):
• During busy periods the flush volume is reduced so that only the bowl is rinsed between two users.
At the end of the busy period a full flush rinses the entire bowl and replaces all the water in the trap.
• The sensor detects the user after a fixed period of 10 seconds. Once the user leaves, the system
carries out a short rinse (timing T1). If another user arrives within the next 20 seconds another short
rinse takes place when he leaves. If no one arrives within the next 20 seconds the system carries out
an additional rinse (timing T2).
• TEMPOMATIC 4 has 3 rinsing options depending on the type of urinal.
The timing for T1 and T2 are set-up at the same time.
- Position 1: T1 = 2 seconds; T2 = 2 seconds
- Position 2: T1 = 2 seconds; T2 = 4 seconds
- Position 3: T1 = 3 seconds; T2 = 8 seconds
Hygienic duty flush: automatic flush for a period equal to T1 + T2 seconds every 24 hours after the last
use (prevents backflow and reduces bad smells).
GENERAL FEATURES
• This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• This appliance is intended to be household and indoor used only.
INSTALLATION
• Ambient operating temperature: 7 - 40°C.
• Water supply: 1 to 5 bar maximum (100 to 500 kPa), (minimum 2 (200 kPa) bar for siphon-action urinals).
• Power supply: CR123A 3V lithium batteries.
REMEMBER
• Our valves must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer
(see calculation table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure from 1 to 5 bar (100 to 500 kPa) maximum).
• Install stopcocks close to the valve to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should
be checked at least once a year, and more frequently if necessary.