LP gas tank must be arranged for vapor withdrawal
It is essential to keep the outdoor appliance's valve compartment, burners,
and circulating air passages clean. Inspect outdoor appliances before each
use. This outdoor appliance should be thoroughly cleaned and inspected on a
regular basis. Clean and inspect the hose before each use of the appliance. If
there is evidence of abrasion, wear, cuts, or leaks, the hose must be placed
prior to the appliance being put into operation.
LP Tank used must include a collar to protect the cylinder valves
The LP gas tank must have a listed overfilling prevention device ( OPD ) and
QCC or Type I ( CGA791 ) LP gas tank connection.
The LP gas tank should not be dropped or handled roughly
Tanks must be stored outdoors out of the reach of children. Do NO store in
buildings, garages, or other enclosed areas.
Never store your LP gas tank where temperatures can reach over 125 °F.
Never keep a filled LP gas tank in a hot car's rear trunk. Heat will cause the
gas pressure to increase, which may open the relief valve and allow gas to
escape.
Place dust cap on valve outlet whenever the LP gas tank is not in use. Only
install the type of dust cap on the LP gas tank valve outlet that is provided with
the gas tank valve. Other types of caps or plugs may result in leakage of
propane.
Do not store a spare LP gas tank under or near this gas appliance ever fill the
tank beyond 80% full.
LP gas cylinders should only be filled by a certified LP gas supplier.
The pressure regulator is set for 11 inches of water column ( pressure )
Any guard or other protective device removed for servicing the appliance must
be replaced prior to operating the appliance.
Installation and repair should be done by a qualified service person.
The appliance should be inspected before use and at least annually by a
qualified service person. More frequent cleaning may be required as
necessary. It is imperative that the control compartment, burners, and
circulating air passageways of the appliance be kept clean.
The appliance should be inspected before use and at least annually by a
qualified service person.
Do not attempt to disconnect the gas regulator from the tank or any gas fitting
while the outdoor appliance is in use.
Keep the gas appliance away from locations where it can get excessively wet.
Do not use the gas appliance if any part has been underwater.
Immediately call a qualified service technician to inspect the appliance and
replace any part of the control system and any gas control which has been
underwater.
10
This appliance shall be used only outdoors in a well-ventilated space and
shall not be used in buildings, garages, or any other enclosed area.
The LP-gas supply cylinder must be disconnected when this appliance is not
in use.
Only cylinder marked propane shall be used.
Be sure to use only one 20lb( 9.1kg ) LP gas cylinder with a Type I valve with
this appliance as required by the American Nati Standards Institute ( ANSI )
and the Canadian standards Steering Committee
Never attempt to attach this appliance to the self-contained gas system of a
camper trailer, motorhome, or house.
Hand turn the manuals control valve. Never use tools. If the valve will not
tumble hand, do not try to repair it Call a Certified Gas Technician. The use
of force oneself attempted repair may result in a fire or explosion.
WARNING: Improper installation, ad, alteration, service or maintenance can
cause injury or property damage. Refer to the owner's information manual
provided with this appliance. For assistance or additional information,
consult customer service.
LP Hose and Regulator Assembly and Replacement
1. This appliance comes equipped with a standard P gas hose and regulator
including the appliance side connection for a CGA No791 Cylinder
Connection Device. The P gas hose and regulator supplied with this
appliance must be used Only a hose and regulator specified by the
manufacturer can be used for replacement.
a) The CGA No79iconnectionincorporates an excess flow limiting device that
acts to limit the flow of gas if a leak is detected between the regulator and
the burner valve.
b ) If the burner valve is open prior to help gas cylinder service valve being
opened, the connection will interpret this free flow of Gas to be a leak.
c ) The connection safety feature will reduce gas flow from the regulator to
the appliance to a minimal level.
d ) Be sure that the user control valve is closed prior to opening the LP gas
cylinder service valve to ensure that the connection flow limiting device is not
triggered mistakenly.
e) If the connection flow limiting device is triggered mistakenly, close the gas
cylinder service valve and the burner valve, wait for 10 seconds to allow the
device to reset, open the cylinder service valve, then open the burner valve
and light the appliance as perlighting instructions.
2. Be sure to protect the hose from any hot surfaces. Serious danger may
result if the hose contacts any hot surface.
3. Regular maintenance of the hose and regulator:
a) Inspect the hose before each use of the appliance. If the hose shows
11