Télécharger Imprimer la page

CEMO KS-Mobil 90 l Mode D'emploi page 31

Masquer les pouces Voir aussi pour KS-Mobil 90 l:

Publicité

Les langues disponibles

Les langues disponibles

i
Important!
Positive fit before traction!
First, try to positively load the equipment
(e.g. through striking the sides).
Excessive lashing forces can damage
the tank.
Recommendation:
Use a non-slip mat.
5.4 Filling the tank
1. Only fuels that are dispensed at public filling sta-
tions may be filled (max. ethanol content 15 %).
Important!
Risk of explosion.
Avoid sources of ignition, such
as smoking or naked flame.
2. Pay attention to the horizontal alignment and
ensure the tank is adequately secured!
3. Create equipotential bonding (earthing) between
the tank and transport vehicle or ground for non
conductive surfaces.
4. Open the pump enclosure clamp lock and cover.
5. Unscrew the cap from filling opening b.
The container may only be filled with a
self-closing delivery nozzle!
6. Check the level inside the tank by unscrewing
the dipstick cap and pulling out the dipstick d.
7. Screw the cap of the filling opening and dipstick
back on tightly.
8. Contamination caused by the filling process
must be removed immediately with a dry cloth.
9. Close the cover of the pump enclosure,
lock the clamp lock.
All manuals and user guides at all-guides.com
5.5 Filling
5.5.1 General
Ban on fire, naked flames
and smoking.
Important!
Risk of explosion.
Ensure sufficient ventilation in the area
of the tank during the filling operation.
i
Important!
Comply with the specified Ex­zone
(see section 1.2 and 1.3)
and always monitor the filling procedure.
• Tank ventilation a is performed automatically
by the integrated non-return valve.
• Pay attention to the horizontal alignment
and that the tank is adequately secured!
• Check the level inside the tank by unscrewing
the dipstick cap and pulling out the dipstick d.
5.5.2 Filling with hand pump
1. Create equipotential bonding (earthing) between
the tank and transport vehicle or ground for non
conductive surfaces.
2. Open the pump enclosure clamp lock and cover.
3. Open delivery line ball valve c.
4. Remove the hose h and delivery nozzle g
from the pump enclosure and insert the delivery
spout fully into the tank/container to be filled.
5. Operate or open the delivery nozzle g.
6. Move the hand pump  vertically up
and down and start the filling procedure.
i
Important!
Operate the hand pump only when the ball
valve and delivery nozzle are open.
Operation without liquid is only permitted
for brief periods of time.