SP-330, SP-330D, SP-500, SP-500A Submersible Sump Pumps
Specifications
Motor:
Type .....................................Shaded Pole
Rating ..................................120V, Single Phase
Pump
1/3 HP..................................3100 GPH @ 0 Ft.
1/2 HP..................................4400 GPH @ 0 Ft.
Liquid temperature range ....40F to 120F
Cut in level...........................9"
Cut out level.........................4"
Performance Curve
25
20
15
10
5
1000
2000
0
Gallons Per Hour
Performance Chart
Model
Discharge Head
SP-330
Gallons/Hour
SP-330D Gallons/Hour
SP-500
Gallons/Hour
SP-500A Gallons/Hour
Pump Installation
DANGER
!
• Pump should only be used to pump clear
water. Do not use to pump fluids such as gaso-
line, fuel oil, or kerosene. Do not use in a flam-
mable or explosive atmosphere. Improper use
could result in personal injury and/or death.
WARNING
!
To prevent property damage,
serious injury, or death, proper installation of the
pump is required. The following procedures
should be followed:
4
All manuals and user guides at all-guides.com
1/3 HP, 9.5 Amps
1/2 HP, 10 Amps
SP-300
SP-300D
SP-500
SP-500A
3000
4000
5000
6000
0'
5'
10'
15'
3100 3000 2700 1680
3100 3000 2700 1680
4400 4100 3200 2000
4400 4100 3200 2000
Ridge Tool Company
• Pump must be plugged into an outlet recepta-
cle that includes a Ground Fault Circuit
Interrupter (GFCI) (Figure 1) .
• Always disconnect the power source before
attempting to install, service, relocate, or main-
tain the pump. Never handle a pump or pump
motor with wet hands or when standing on wet
or damp surface or in water.
Installation
1. Construct a sump pit from concrete, steel, or plas-
tic that is 24" deep and at least 11" in diameter
(Figure 2 next page) . If the sump already exists,
make sure it is the proper size.
2. Make sure the electrical outlet is grounded and is
rated for 115 volts and at least 15 amps. The out-
let must be protected by a Ground Fault Circuit
Interrupter (GFCI).
WARNING
!
Use of a grounded receptacle that
is protected by a GFCI reduces risk of a fatal electrical
shock.
3. Inspect the power cord and plug for damage. If the
plug is missing the grounding prong or the cord is
damaged, do not install the pump until the cord has
been replaced.
(Model SP-330D Diaphragm Switch only)
4. Remove the two fasteners in the cast iron volute
near the discharge area. Align the hole with the
diaphragm switch and replace the fasteners with-
out over tightening.
Figure 2 – Submersible Pump Installation