c) Using the microphone
1. Turn on your computer/audio device with the connected sound generators
(loudspeakers). If necessary, launch your audio software.
2. Turn the sensitivity of your audio software/device to zero using the corresponding
input level control (refer to the operating instructions of the device you are using).
3. Insert a pair of headphones with a 3.5 mm jack into the headphone socket (6) on
the microphone.
4. Test the microphone by speaking a few words whilst slowly moving the input level
control on the audio device upwards until the desired output volume is reached.
Maintenance and cleaning
• The product does not require maintenance except for occasional cleaning.
• Under no circumstances should you service any of the components in the interior of
the device, therefore never open it.
• Before cleaning, remove the USB cable from the connected computer/audio device.
• Use a soft, antistatic and lint-free cloth to clean the device. Dust can be easily
removed using a soft and clean long-haired brush.
• Never use aggressive and abrasive detergents, rubbing alcohol or other chemical
solutions, as these could damage the casing or even impair the functioning of the
product.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the
relevant statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of the
environment.
All manuals and user guides at all-guides.com
Technical data
Operating voltage................................5 V/DC (via USB)
Frequency response ...........................0.030 kHz – 18 kHz
Sensitivity .............................................-32 dB (0 dB=1 V/Pa, 1 kHz)
Max. sound pressure..........................130 dB (1 kHz ≤ 1 % Total harmonic distortion)
Headphone output power ..................400 mW
Directivity .............................................Cardioid
Sampling Rate......................................16 bit / 48 kHz
Working principle ................................Condenser microphone
System requirements ......................... Windows
Connection ...........................................USB 2.0
Cable length .........................................1.8 m
Operating conditions ..........................-10 to +60 °C, 95 % RH (non-condensing)
Storage conditions..............................-10 to +60 °C, 95 % RH (non-condensing)
Dimensions (Ø x H)..............................53 x 185 mm
Weight ...................................................420 g
Analogue-digital conversion
Sampling frequency............................8 / 11.025 / 16 / 22.05 / 32 / 44.1 / 48 kHz
Total harmonic distortion ...................0.01 %
Signal-to-noise ratio ..........................89 dB
Dynamic range ....................................89 dB
Digital-analogue conversion
Sampling frequency............................32 / 44.1 / 48 kHz
Total harmonic distortion ...................0.005 %
Signal-to-noise ratio ...........................96 dB
Dynamic range ....................................93 dB
Frequency response
Directivity
dB
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright 2015 by Conrad Electronic SE.
XP, Vista™ 7, 8, Mac
®
Hz
V1_0615_02-DS

Publicité

loading