Makita BFL201R Manuel D'instruction page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Status of the LED indicator/beeper
LED indicator
Lights up in
yellow.
Blinks in red
and yellow
alternatively.
Blinks in red
and blue
alternatively.
011058
Note: These values can be changed on PC. Refer to
SRCV02 USER MANUAL for details.
Beeper
Result of torque
A long beep
judgment: NOK
(Low)
Warning against
insufficient
fastening
Double-hitting
detection
A long beep
Angle judge NOK
Rundown NOK
Torque impossible
monitoring
Disconnection
(when using
receiver RCV02)
A series of short
beeps
Radio
communication
failure
Function
This function works
when the tool has
reached below the
fastening torquer
ange preset on PC.
(Note)
Fastening is
imcomplete when
switch trigger of tool
is released before
clutch activation.
This function works
when a screw is
refastened after
fastening.
This function works
when a screw is not
fastened within the
angle range preset
on PC (Note).
This function works
when a fastening is
finished before it
reaches the preset
angle range. (Note)
This function works
when torque monitoring
is cannot be carried out.
Radio communication
not yet established
This function works
when there is radio
communication failure.
8
Status
Action to be taken
Finish necessary
connection or
remove a battery
cartridge to escape.
Take it to a Makita
Authorized Service
centers.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bfl301rBfl402r

Table des Matières