MAX. TEMPERATURE OF PUMPED LIQUID
MAX. FREE PASSAGE
MAXIMUM SAND QUANTITY
MAX.ON/OFF CYCLES/HOUR
MINIMUM WELL DIAMETER
MAX. IMMERSION DEPTH
CH. 4 - MOTOR ASSEMBLY
K-SERIES, SCM 4 PLUS®, SCM 4 HF and SA 6 pumps are designed to be coupled with 4" motors (K-SERIES, SCM
4 PLUS®, SCM 4 HF and SA 6) and 6" motors (SA 6) in accordance with NEMA standards.
Perform the following operations to guarantee a correct coupling:
- remove the raceway that protects the cable and the sand-protection filter
- manually check the rotation of the motor shaft and the hydraulic unit
- verify that the coupling and the coupling axis are clean
- join the pump body and the motor, verifying that the electric cable is correctly positioned next to grooves on the
hydraulic unit supports
- tighten the nuts on the 4 motor tie rods, alternatively on the diagonals
- position the electric cable along the pump and reassemble the protection raceway by tightening the screws to the
hydraulic unit
- fix the sand protection filter to the lower support of the hydraulic unit body by using the screws provided for this
purpose
CH. 5 - ELECTRIC PUMP INSTALLATION (see fig. 1)
Electric pump cannot be used to move
WARNING
inflammable or dangerous liquids.
Ensure electric pump never runs dry
WARNING
When installing, please ensure unit is
DANGER
disconnected from electrical supply.
Risk of electric
shock
When installing, please ensure pump is disconnected
DANGER
from electrical supply.
Risk of electric
shock
DANGER
Never use the electric cable to support the electric pump.
Risk of electric
shock
DANGER
Be careful not to damage the electric cable when lowering
Risk of electric
it into the well.
shock
DANGER
This type of pump can develop high pressure. If a
collection tank or expansion tank 15 is to be installed, it
Risk of bursting
is advisable to install a pressure limiter valve 16 between
the tank and the pump.
DANGER
All of the pipes and installation parts must have a
maximum working pressure which is greater or equal to
Risk of bursting
the maximum pressure of the pump, if this is not possible
it is necessary to use a pressure reducer.
WARNING
Protect the electric pump and all pipes from freezing.
30° C (K-SERIES, SCM 4
3 mm
50 g/m
(SCM 4
)-40 g/m
3
®
20 (K-SERIES, SCM 4
)-15 (SA 6) equally
®
distributed
100 mm (K-SERIES, SCM 4
150 m
GB
)-25° C (SA 6)
®
(SA 6)
3
)-150 mm (SA 6)
®
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Scm 4 plusScm 4 hfSa 6

Table des Matières