SPECIFICATIONS
AC ELECTRICAL RATINGS:
UL and CSA recognized for resistive loads.
Temp Control
Voltage
30 Amps
120-250 VAC
25 Amps
277 VAC
12.5 Amps
480 VAC
INSTALLATION
All wiring must conform to local and national electrical codes and ordinances.
Connect in accordance with wiring diagrams provided by the equipment manufacturer. If none are provided,
the following represents a typical installation.
L1
1
3
2
4
754-1
Field
Installed
1
Jumper
2
755-1
Heating Element
120 VAC Single Element
Circuit for Full Power
Disconnect
SETTING THE DIAL
Adjust temperature setting by inserting a screwdriver into
open slot and turning pointer to desired temperature on
dial.
All manuals and user guides at all-guides.com
Limit Control
40 Amps
40 Amps
25 Amps
N
L1
1
2
Field
Installed
1
Jumper
2
Heating Element
240 VAC SIngle Element Circuit
for Full Power Disconnect
Through Both Power Conductors
Temperature Ratings:
Temperature control - Variable 90° to 150°F (32° to
Limit control - Fixed 170°F (77°C) with manual reset
Wiring
L2
3
4
754-1
755-1
150°F
66°C
66°C)
Two-Element
Non-Simultaneous Operation
L1
L2
1
3
2
4
754-1
Field
Installed
4
Jumper
1
2
756-1
Upper Heating
Element
1
2
755-1
Lower
Heating Element
240 VAC Double Element
Limited Demand Circuit for
Full Power Disconnect
Through Both Power Con-
ductors
Adjustment Slot
90°F
32°C
125°F/52°C