WHITE-RODGERS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
This control is designed to meet the high electrical capac-
ity requirements of electric water heaters.
The temperature control is a normally closed switch
which opens on a rise in temperature. The SPST version
(755-1) will control one heating element. The SPDT
version (756-1) will control two heating elements when
used with W-R type 755-1. (See wiring diagrams.)
THIS CONTROL MUST BE INSTALLED BY A QUALI-
FIED INSTALLER.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
This control has been accurately calibrated at the factory.
Any attempt to re-calibrate this control will void the White-
Rodgers warranty.
WARNING
!
Do not use on circuits exceeding specified volt-
ages. Higher voltages will damage control and
could cause shock or fire hazard.
If in doubt about whether your wiring is millivolt,
low or line voltage, have it inspected by a quali-
fied heating and air conditioning contractor or a
licensed electrician.
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
All manuals and user guides at all-guides.com
Printed in U.S.A.
754-1, 755-1, 756-1
Electric Water Heater Control
INSTALLATION INSTRUCTIONS
The limit control (754-1) is a normally closed DPST switch
which opens on a rise in temperature to limit the maximum
allowable temperature. It has manual reset.
Both switches are calibrated to meet the requirements for
typical residential type storage tank water heaters.
CAUTION
!
To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.
Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper
and dangerous operation.
Following installation or replacement, follow
appliance manufacturers' recommended instal-
lation/service instructions to insure proper op-
eration.
DESCRIPTION
PRECAUTIONS
PART NO. 37-5787A
9722

Publicité

loading

Sommaire des Matières pour White-Rodgers 754-1

  • Page 1 PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION This control is designed to meet the high electrical capac- The limit control (754-1) is a normally closed DPST switch ity requirements of electric water heaters. which opens on a rise in temperature to limit the maximum allowable temperature.
  • Page 2 All wiring must conform to local and national electrical codes and ordinances. Connect in accordance with wiring diagrams provided by the equipment manufacturer. If none are provided, the following represents a typical installation. Two-Element Non-Simultaneous Operation 754-1 Field Installed 754-1 Field...
  • Page 3 BLESSURES ET/OU D’ENDOMMAGER L’ÉQUIPEMENT. DESCRIPTION Cette commande est conçue pour satisfaire les spéci- Le commutateur de seuil (754-1) est un commutateur fications électriques des chauffe-eau électriques. bipolaire fermé au repos dont l’ouverture est déclenchée par une augmentation de la température pour limiter la La température est réglée par un interrupteur fermé...
  • Page 4 électriques locaux et nationaux. Effectuer les connexions conformément aux schémas de câblage fournis par le fabricant. Si aucun schéma n’est fourni, les schémas suivants représentent une installation type. Deux éléments fonctionnement non simultané 754-1 Fil de Field liaison raccordé Installed...
  • Page 5 PRODUCIR LESIONES PERSONALES Y/O DAÑO A LA PROPIEDAD. DESCRIPCION Este control ha sido diseñado para cumplir con los El control de límite (754-1) es un interruptor bipolar, de requisitos de las capacidades eléctricas altas de los una posición, que se abre cuando la temperatura aumenta calentadores de agua, eléctricos.
  • Page 6 Todo el cableado tiene que cumplir con las regulaciones y los códigos eléctricos nacionales y locales. Conéctelo según los diagramas de cableado que ofrece el fabricante del equipo. Si no se ofrece ninguno, los dia- gramas a continuación presentan la instalación típica. Operación de Dos Elementos, No Simultánea 754-1 Cable de empalme Field instalado en...

Ce manuel est également adapté pour:

755-1756-1