KeY Features
DeVilbiss intellipap Device
(Figures a and B)
1.
Keypad/LCD Display (see Figure C)
2.
Air Supply Port on Back
3.
Air Supply Port on Bottom (for optional humidifier)
4.
Air Supply Port Plug
5.
Heater Power Connector (for optional humidifier)
6.
AC Power Connector
7.
DC Power Connector
8.
Data Port
9.
Power Cord (appropriate to your wall outlet) (not
shown)
10. Air Inlet Filter Opening
11
Connector Cover (not shown)
Keypad
(Figure c)
1.
On/Off
2.
Previous Item
3.
Next Item
4.
Delay
5.
Decrease Value
6.
Increase Value
7.
Heater Power LED (for optional humidifier)
Ask your equipment provider for information about other
DeVilbiss masks, equipment, and accessories.
sYsteM asseMBlY
Without Heated Humidification
1.
Locate the air supply port and heater power connector on the bottom of the IntelliPAP device. Ensure that each
opening has the appropriate soft cover securely attached.
2.
Place the IntelliPAP on a stable surface such as a nightstand or table. If you wish, you may also place the device on
the floor at the bedside, being careful to place the unit where it won't be kicked or stepped on. Ensure that the air
inlet in the back of the device is not blocked by anything such as curtains or bedding.
NOTE
Never place the IntelliPAP system on a soft surface such as a bed or couch during operation.
With Heated Humidification
CAUTION–The height of the IntelliPAP must be lower than the mask when using a humidifier to prevent water from getting
into mask.
1.
If your system includes a humidifier, please follow steps in Figures 1-7.
a.
Locate the heater power connector on the bottom of the device. Remove the connector cover and insert it into
the storage opening in the bottom of the humidifier cradle.
b.
Locate the air supply port at the bottom of the device. Remove the port plug and insert it into the air supply
port in the back of the device.
c.
Place device onto humidifier cradle and click into place.
d.
F ill clean chamber to fill line with distilled water and insert into cradle. NOTE-Always use distilled water to
avoid mineral buildup inside the chamber. Do not overfill.
KeYpaD aND DisplaY
Basic cpap controls
Name
Symbol
ON/OFF
HEATER
DELAY
NOTE– The left and right arrow keys on the control panel provide access to menus for specific settings. Ask your
homecare provider for more information.
eN - 6
(page 2, Figures a-F)
Function
The ON/OFF button starts and stops the flow of air from the device.
If your IntelliPAP has a heater/ humidifier attached, these buttons adjust the heater setting.
Increase the setting for more humidity and decrease the setting for less humidity.
The Delay button activates the comfort delay feature and only functions if this feature has been
enabled. To understand how to set the parameters of this feature, please refer to the Using the
Comfort Delay Feature found on page EN - 9.
Humidifier cradle
1.
Heater plate
2.
Heater power connector
3.
Storage compartment for connector cover (on
bottom)
4.
Air supply port inlet
5.
Air supply port outlet
6.
Flow generator release button
7.
Flow generator locking tabs
Water chamber
1.
Chamber lid
2.
Chamber base
3.
Heat transfer plate (on bottom)
4.
Sealing gasket
5.
Water level indicators (front and sides)
6.
Chamber release latch
7.
Chamber disassembly lever
therapy Management system
1. SmartLink
(optional)
®
(Figure D)
(Figure e)
(Figure F)
A-DV57