4.
Overview
Refer to the illustrations on page 2 of this manual.
1
connection box
2
negative terminal
5.
Connection
Use a suitable cable – preferably a UV-resistant cable with section 1-2.5 mm² - depending on the
1.
length of the cable and the size of the panel.
2.
Open the connection box. Thread the cable through the cable clamp. Carefully check the polarity
markings on the terminal block and connect the positive and negative wires accordingly. There are
polarity markings next to the cable clamp screws.
6.
Tips
6.1
General
Coat the wires and terminal posts with Vaseline
Make sure that the cable clamp is tightened.
Close the lid of the connection box tightly to prevent moisture from entering.
If the solar module is to be mounted in a coastal area, it is extra important to protect the installation
from moisture to prevent saltwater corrosion.
6.2
General
The solar module should be connected to a battery system via a charge controller.
If more than one panel is used, they can be connected in either series or parallel.
V. 02 – 13/06/2017
SOL10P/SOL30P/SOL60P
3
®
to protect them from corrosion.
4
positive terminal
©Velleman nv