C) Set the Outlet Pair to SWITCHED ON AFTER DELAY: Press MENU until the display shows the status
of the Analog outlet pair. Press the SELECT button until the time delay changes to the required delay
in seconds before the outlet pair will turn on after the ON/OFF button is pressed.
When the PowerSource is SWITCHED ON by pressing the front panel ON/OFF button, or by an external trigger signal,
the outlet pair will go "live" after the time delay set as described above — 20 seconds in this case. The outlet pair
with the maximum time delay setting will still turn off immediately when the ON/OFF button is pressed,
or when triggered by an external signal.
D) Set the Outlet Pair to UNSWITCHED (Always On): Press the MENU button until the display shows the status
of the Analog outlet pair. Press the SELECT button until you see the display.
Once UNSWITCHED is selected, any component plugged into those outlets will receive power continuously
as long as your PowerCenter is plugged into a 120 volt outlet that is on.
Note: The unit is shipped with all outlet pairs set to SWITCHED ON.