6. For more effective results use for at least seven consecutive days. Between 6 AM and 8 PM for two hours
per day.
7. Start with shorter periods of illumination and increase over the course of a week.
NOTE: Eye aches and mild headaches may occur for the first uses and will subside after continued usage.
8. Press the On/Off Button to shut the unit off. Unplug the power adapter from the electrical outlet.
CAUTION
The lamp remains hot after use. Let the lamp cool before storing.

7. Care and Storage

• Before cleaning the unit, always switch it off, unplug it, and let it cool.
• Do not immerse unit in water or other liquids. Use a slightly damp cloth to clean the device. Do not use
abrasive detergents.
• Do not touch the unit with wet hands while it is plugged in; do not allow any water to be sprayed onto the
unit. The unit must be operated only when it is completely dry.
• If you are not going to use the device for an extended period of time, disconnect it and store it in a dry
place, out of the reach of children.

8. Troubleshooting Guide

Problem
Device does not light up

9. Specifications

Model
Type
Dimensions (WHD)
Weight
Lighting elements
LED lifetime
Power
Light intensity
Radiation
Operating conditions
Storage conditions
Product classification
Color temperature
Adapter Model
Power Adapter Input
Possible cause
On/Off Button switched off.
No electricity.
No electricity.
LEDs have reached the end of their
service life or are faulty.
TL 30
WL11
approx. 9.3 in x 6.1 in x 1.0 in (236 x 156 x 26 mm)
approx. 11.6 oz (330 g) (14.3 oz (405 g) incl. mains adapter + storage pouch)
LED (E
<4x10
W·m
·nm
-5
-2
λ
10,000 hours
5 Watts
approx. 10.000 lux (in a distance of 3.9 in (10 cm))
Output of radiation beyond the visible spectrum (infrared and UV) is so low
that it is harmless to eyes and skin.
32 °F to 95 °F (0 °C to 35 °C), 15 – 90 % relative humidity
-4 °F to 122 °F (-20 °C to 50 °C), 15 – 90 % relative humidity
External power supply, Protection class II, IP21
6.500 °K
UES06WU-120046SPA
(DONGGUAN SHILONG FUHUA ELECTRONIC CO LTD)
100 – 240 V ~50/60 Hz, 0.2 A
5
Solution
Switch on the On/Off Button.
Connect the power cord properly.
The power cord is faulty.
Contact customer service.
Contact customer service.
, L
<0.05 W·m
·sr
·nm
-1
-2
-1
λ
)
-1

Publicité