28
www.aeg.com
Problem
The lamp does not work.
The compressor operates
continually.
There is too much frost and
ice.
Water flows on the rear
plate of the refrigerator.
Water flows inside the refrig-
erator.
Water flows on the floor.
Possible cause
The mains plug is not con-
nected to the mains socket
correctly.
There is no voltage in the
mains socket.
The lamp is in stand-by.
The lamp is defective.
Temperature is set incor-
rectly.
Many food products were
put in at the same time.
The room temperature is
too high.
Food products placed in
the appliance were too
warm.
The door is not closed cor-
rectly.
The door is not closed cor-
rectly or the gasket is de-
formed/dirty.
The water drainage plug is
not correctly positioned.
Temperature is set incor-
rectly.
During the automatic de-
frosting process, frost
melts on the rear plate.
Food products prevent the
water to flow into the wa-
ter collector.
The water outlet is clog-
ged.
The melting water outlet is
not connected to the
evaporative tray above the
compressor.
Solution
Connect the mains plug to the
mains socket correctly.
Connect a different electrical
appliance to the mains socket.
Contact a qualified electrician.
Close and open the door.
Refer to "Replacing the lamp".
Refer to "Operation".
Wait few hours and then check
the temperature again.
Refer to climate class chart on
the rating plate.
Allow food products to cool to
room temperature before stor-
ing.
Refer to "Closing the door".
Refer to "Closing the door".
Position the water drainage
plug in the correct way.
Refer to "Operation" .
This is correct.
Make sure that food products
do not touch the rear plate.
Clean the water outlet.
Attach the melting water out-
let to the evaporative tray.