SOLID FUEL NATURAL VENTILATION
SOLID FUEL FORCED VENTILATION
7.

HYDRAULIC INSTALLATION

Bronpi "hydro" series has been designed for installation with a closed expansion vessel, where the water contained does not communicate
direct or indirectly with the atmosphere. In general, the installation of closed expansion vessel is provided with a pre-charged closed vessel
with a gas-tight membrane.

SAFETY VALVES

The boiler or thermo-stove is provided with a safety valve set at 3 bars pressure, in order to work during possible increases of pressure on the
installation.
The discharge flow rate of the safety valve must allow to discharge an amount of vapour not lower than Q / 0.58 [kg. h], where Q is the useful
power transferred to the water of the generator expressed in kilowatts.
The fitter must control the maximum pressure in each point of the installation so that it does not pass the maximum working pressure of each
component.
The safety valve is placed on the top of the boiler or thermo-stove, next to the exit tube. The discharge tube of the safety valve must be made
so that it allows the normal operation and does not cause damages to people; the discharge must end near to the safety valve and be visible
and accessible.