1.
DEFINITION OF SYMBOLS
This symbol highlights those parts of the text that try to avoid mistakes when handling the thermo-stove and boiler. The omission of
these instructions may cause material damages and, in the case of wrong handling, damage to the health.
This symbol highlights those parts of the text that try to help for a better understanding of the adjustment/control of the boiler and
the thermo-stove or the heating circuit.
2.
GENERAL WARNINGS
The installation of a boiler or thermo-stove must be done according to the local, national or European regulations.
Boilers and thermo-stoves by Bronpi Calefacción, S.L. are manufactured under a quality control system in order to protect both the user and
the fitter in the event of possible accidents. We also recommend to the authorized installer that, each time an operation in the boiler or thermo-
stove is going to be done, pay special attention to the electrical connections, especially that stripped or bear wires are never left outside the
connections, avoiding dangerous contacts.
The installation must be performed by authorized personnel who must provide the buyer with a declaration of conformity of the
installation where he will assume full responsibility for the final installation and, therefore, the proper operation of the product
installed. Bronpi Calefacción S.L. will not assume any liability in the case of failure to comply with these precautions.
The manufacturer will not assume any liability for damages caused to third parties due to improper installation or misuse of the boiler or
thermo-stove.
In order to ensure the correct operation of the product, components can only be replaced with original spare parts and by an authorized
technician.
Maintenance of the stove or boiler must be performed at least once a year by an Authorized Technical Service engineer.
For your safety and security you should consider:
•
Do not touch the thermo-stove or boiler with bare feet or with wet body parts.
•
The doors of the machine must be closed during operation.
•
It is forbidden to modify the safety or regulating devices without the permission of the manufacturer.
•
Avoid direct contact with any parts of the product that tend to reach high temperatures during its operation.
3.
GENERAL DESCRIPTION
The boiler or thermo-stove that you have purchased contains the following pieces:
•
Complete structure of the boiler or thermo-stove on the pallet.
•
Inside the combustion chamber you can find: a box/bag with a thermal glove for operation of the door handle and other components.
The electrical interconnection cable between the boiler or thermo-stove and the electrical network. A remote control is included in the
thermo-stoves (battery included). A yellow leaflet with the most important warnings and considerations. A book in order to register all
maintenance tasks performed to the boiler or thermo-stove as well as this installation, use and servicing manual.
•
Inside the combustion chamber you will also find the burner and the ash pan.
The boiler or thermo-stove consists of a set of steel plates of different thickness welded together. It is provided with door or viewer with
ceramic glass (resistant up to 750°C) and ceramic rope seal to maintain the integrity of the combustion chamber.
In the case of thermo-stoves, heat of the surrounding environment is produced by radiation: through the ceramic glass and the boiler body,
the heat is radiated into the environment. In Utility boiler models, due to their thermal insulation, this radiation is of low calorific value, so
its performance and the power transferred to water are greatly increased. The central heating heat is radiated through the hydraulic circuit
(radiators, panels, under-floor heating, etc). The boiler or thermo-stove reaches a high thermal efficiency through the use of a high surface
and large water capacity heat exchanger that completely surrounds (side, top and bottom) the combustion chamber.
4.
SAFETY DEVICES
Bronpi boilers have several safety systems that guarantee a safe and an appropriate operation and protect both the boiler and the
user. Some of them are described below. If in doubt, see sections 6.5 and 6.6.
•
Ignition failure
If a flames does not appear during the ignition process, the display will show the message "IGNITION FAILURE". If you try to
ignite the machine again, the display will show the message "AWAITING COOLING".
This function serves to remind that before carrying out the next ignition it is necessary to check that the burner is completely clear
and clean.
•
Smoke extractor fan breakdown
If the extractor fan stops, the electronic card automatically blocks the fuel supply.
•
Breakdown of the fuel loading motor
If the geared motor stops, the boiler or thermo-stove keeps on working but ceases to add fuel until the minimum working smoke temperature
goes down and stops.
In the case that the geared motor rotates continuously (i.e fails in feeding state), the machine will go into an alarm state and cut the fuel
supply.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
31
THERMO-STOVES AND BOILERS WITH AUTOMATIC CLEANING