Before Use
Before you connect the equipment to the mains supply make sure that the data on
the rating plate are identical to the mains data.
Always pull out the power plug before making adjustments to the equipment.
The cable hoist is not suitable for transporting hot and/or molten masses and in
addition it is not suitable for use at low temperatures or in aggressive atmospheres.
It is in mechanical group M1.
The service life of the cable hoist is approximately 8000 cycles (excluding wearing
parts). When the hoist has completed 8000 cycles, all its mechanical parts must be
checked and overhauled.
Read and absorb the operating instructions before you use the cable hoist.
Ensure that the operator knows how the machine works and how it should be
operated.
The user should always operate as set out in the operating instructions.
The cable hoist is not designed for continuous operation. Its mode of operation is:
Intermittent mode without influencing the starting process.
The rated capacity of the machine does not vary due to the position of the load.
Ensure that the operator knows how the machine works and how it should be
operated.
The user should always operate as set out in the operating instructions.
The cable hoist is not designed for continuous operation. Its mode of operation is:
Intermittent mode without influencing the starting process.
The rated capacity of the machine does not vary due to the position of the load.
Operation
Check whether the emergency stop switch is pressed. Turn the red stop switch
clockwise to release it.
Press button ▲ to raise the load.
Press button ▼ to lower the load.
The cable hoist will stop if the emergency stop switch is pressed. In an emergency,
immediately press the emergency stop switch to stop the cable hoist. The cable hoist
cannot be operated if the emergency stop switch is pressed.
Block and Tackle Function
The cable hoist is fitted with a return roller and an additional hook. If these parts
are used correctly, the cable hoist can lift twice its rated load.
Fit the return roller and additional hook. The permanent hook must be attached to
the fastening hole. The load is now raised by two steel cables, which means that the
cable hoist can lift twice its rated load.
Automatic Stop Mechanism Lever
When the maximum lifting height has been reached, the cut-out weight presses the
lever upwards. This trips a limit switch after which the load cannot be raised any
further.
Lever for Maximum Cable Length
When the load has reached its lowest possible position, a limit switch is tripped which
makes it impossible to lower the load any further. This limit switch also prevents the
cable hoist operating in the wrong direction (hook moving in the opposite direction to
the arrow shown on the control switch).