5.
Installation
Unpacking
After opening the packaging, inspect the frame, the steel cable, the hook and the
electric control mechanism for signs of possible transit damage.
Installation
The cable hoist is fitted with two fastening bars with which it has to be fastened to a
rectangular tube. The dimensions of the arm must conform with the size of the
fastening bars and must be capable of supporting twice the rated load. We
recommend that you seek advice from a qualified technician.
All screws must be tightened correctly. A qualified technician should check the
anchoring of the arm before the machine is started.
Remove the adhesive tape from the drum before using the hoist for the first time.
The user should lift the load off the ground at the slowest possible speed. The cable
should be taut when the load is raised.
The motor for the cable hoist is fitted with a thermostat switch. Whilst the cable
hoist is operating, the motor may therefore stop. It will restart automatically when
it has cooled down.
The electric cable hoist is not fitted with a rated power limiter. You should therefore
not repeat attempts to lift a load if the overload trip is limiting the hoist's operation.
In this case the load exceeds the rated capacity of the cable hoist.
Do not leave any suspended loads unsupervised without first taking the appropriate
safety precautions.
Fit the machine with a 10 A fuse or a 10 A residual current operated circuit breaker
(RCCB) to protect the circuit
Do not use the lever as a routine stopping device. It should only be used to stop the
machine in an emergency.
Before you start, ensure that the steel cable is correctly wound around the drum
and that the spacing between the windings is smaller than the steel cable.
Ensure that the load is correctly secured to the hook or, if you are using the block
and tackle, the additional hook and always maintain a safe distance from the load
and the steel cable.
6.
Operation
Purpose
The appliance is designed for lifting and lowering loads in enclosed areas according
to the appliance's capacity.
The appliance is to be used only for its prescribed purpose. Any other use is deemed
to be a case of misuse. The user/operator and not the manufacturer will be liable for
any damage or injuries of any kind caused as a result of this.
Please note that the appliance has not been designed for use in commercial, trade
or industrial applications. The warranty will be voided if the appliance is used in
commercial, trade or industrial businesses or for equivalent purposes.