5. ELECTRICAL CONNECTION
• The thermodynamic water heater
must have a constant supply to guarantee
the production of domestic hot water and the
operation of the titanium impressed current
anode.
• The thermodynamic water heater must not
be electrically connected until it has been filled
with water and the pipes connected.
Never supply the heating element directly with
power.
Single tariff
connection
Power
protected
by RCD
30mA
N
16A
N
Distribution panel
By default, the interface language is French. To change the interface to English:
- Hold down the "MODE" and "OK" keys simultaneously for a very brief moment to enter the advanced menu;
- Press "+" to show the "LANG. <> LANGUAGE menu "and" OK "to validate the selection;
- Select the English language (En) with the "+" or "-" key and confirm with the "OK" key.
All menus and interface settings are now displayed in English.