CAUTION: At least two installers are
required due to the weight and size of the
hood.
1. Measure from range top to hood bottom and mark line A. (26"
minimum from range top) .
2. Plum and mark center line.
3. Mark mounting height line B. (14 3/4" from line A)
4. Mark mounting spread from C/L. (11 1/8")
5. Fasten (2) M6 x 1-1/2" screws into studs on line B but do
not tighten all the way. Note: Wood blocking may need
to be added behind the drywall if no studs are present.
Wall anchors may also be used but check local codes
for compliance. Failure to use suitable wall anchors
and screws to hold the weight of the hood could result
in personal injury or damage to the cooking surface or
counter.
6.
Remove tape and (2) screws securing electronics mounting
bracket to hood. Reposition electronics mounting bracket as
shown in (FIG. B #3) and secure to motor housing using the (2)
previously removed screws.
7.
Remove (2) screws securing electrical junction box to
electronics mounting plate. Remove junction box. (FIG. B #1)
8. Remove the (2) aluminum mesh fi lters.
9. Hang hood onto the mounting screws and hand tighten each
screw. (FIG. A #1) Secure third M6 x 1-1/2" screw through inside
of hood into wall for extra support. (FIG. A #2)
10. Center and attach duct cover mounting bracket to wall just
below the ceiling or soffi t using (2) M6 x 1" screws.
11. Install electrical and duct work. Seal duct work with aluminum
duct tape. Re-install electrical junction box with cable lock and
install the electrical. (FIG. B #2)
12. Power up hood and check for leaks around duct tape.
13. Place telescopic duct covers onto hood and extend inner (top)
duct cover upwards and secure to duct cover bracket using (2)
M3.5 x 8 screws.
14. Re-install aluminum mesh fi lters.
* If using hood in recirculating mode you must secure the air diverter
plate onto wall before installing duct work and duct covers. Turn
to page 10 for more details.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
Cable Lock
A cable locking connector (not supplied) might
be required by local codes. Check with local
requirements and codes, purchase and install
appropriate connector if necessary.
11 1/8"
Brackets are
pre-installed
FIG. A
Cable Lock
9
14 3/4"
26" min
1
2
2
1
3
Motor Housing
FIG. B